SERVICE PROGRAM MODE TABLES
096 Default User Name for Backup Files
Sets the user name when the print backup function is used.
Limit: 8 alphanumeric characters.
097 Default Compression for Backup Files
This SP sets the compression rate for JPEG backup files when the print backup
function is used. This SP operates only after SP5826 0094 has been set for "1"
(JPEG).
[0~2/0/1]
098 Capture Setting: Gamma SW for Backup File
Removes the ghost images transferred from the back sides of double-sided
originals.
1: Enable
0: Disable
5839
IEEE 1394
This SP is displayed only when an IEEE 1394 (firewire) card is installed.
007
Cycle Master
Enables or disables the cycle master function for the 1394 bus standard.
[0~1/1]
0: Disable (Off)
1: Enable (On)
008
BCR Mode
Determines how BCR (Broadcast Channel Register) operates on the 1394
standard bus when the independent node is in any mode other than IRM.
(NVRAM: 2-bits)
[Always Effective]
009
IRM 1394a Check
Conducts a 1394a check of IRM when the independent node is in any mode
other than IRM.
[0~1/1]
0: Checks whether IRM conforms to 1394a
1: After IRM is checked, if IRM does not conform then independent node
switches to IRM.
010
Unique ID
Lists the ID (Node_Unique_ID) assigned to the device by the system
administrator.
Bit0: Off
Bit1: On
OFM: Does not list the Node_Unique_ID assigned by the system administrator.
Instead, the Source_ID of the GASP header in the ARP is used.
ON: The Node_Unique_ID assigned by the system administrator is used, and
the Source_ID of the GASP header in the ARP is ignored. Also, when the
serial bus is reset, extra bus transactions are opened for the enumeration.