Ricoh B064 SERIES Service Manual page 485

Hide thumbs Also See for B064 SERIES:
Table of Contents

Advertisement

317
C
Potential sensor calibration error 7
During drum potential sensor
calibration, when VL is adjusted, the
pattern surface potential VL pattern is
not within range 0V ~ –400V. (VL is
the potential after exposing a white
pattern.)
321
D
F-GATE error
The laser writing signal (F-GATE) for
the IPU does not go LOW within 60 s.
322
D
Laser synchronization detector error
After the polygon motor reaches
standard rotation speed and the LD
unit fires for 500 ms, the laser
synchronization detector does not
generate a signal.
335
D
Polygon mirror motor error 1
The ready signal does not go low
within 20 s after the polygon mirror
motor turns on or changes speed.
336
D
Polygon mirror motor error 2
The ready signal does not go high
within 20 s after the polygonal mirror
motor turns off.
337
D
Polygonal mirror motor error 3
The XSCRDY signal goes high while
the polygon mirror motor turns on,
even though there was no request to
either turn off the motor or change the
motor speed.
338
D
Polygonal mirror motor error 4
While the polygon motor is rotating,
the XSCRDY signal goes high during
exposure.
SM
CÓPIA NÃO CONTROLADA
B140/B246/D052 SERIES SERVICE MODE
• Potential sensor defective
• Potential sensor harness
• Potential sensor connector defective
• IOB defective
• OPC connector defective
• Charge corona power pack defective
• Development power pack defective
B140 Only
• BICU board defective
• PCI bus between controller board,
B140 Only
• Harness between detector and I/F
• Detector is installed incorrectly
• Detector board is defective
• IPU board defective
B140 Only
• Harness between I/F and polygon
• Polygon motor or polygon motor driver
• IPU board defective
B140 Only
• Harness between I/F and polygon
• Polygon motor or polygon motor driver
• IPU board defective
B140 Only
• Noise on the line where the polygon
• Harness between the polygon motor
• Polygon motor or polygon motor driver
B140 Only
• Noise on the linef where the polygon
• Harness between the polygon motor
• Polygon motor or polygon motor driver
• IPU board defective
4-47
CÓPIA NÃO CONTROLADA
disconnected
or disconnected
BICU board defective
disconnected or damaged
motor disconnected or defective
defective
motor disconnected or defective
defective
ready signal (XSCRDY) is transmitted.
and I/F disconnected or defective.
defective
ready signal (XSCRDY) is transmitted.
and I/F disconnected or defective.
defective
B064 Series/B140 Series
/B246 Series/D052 Series

Advertisement

Table of Contents
loading

This manual is also suitable for:

B246 seriesB140 seriesD052 series

Table of Contents