4.3.2 B140/B246/D052 SERIES SERVICE CALL CONDITIONS

There are 4 levels of service call conditions.
Level
Fusing unit SCs displayed on the operation
A
panel. The machine is disabled. The user
cannot reset the SC.
SCs that disable only the features that use the
defective item. Although these SCs are not
B
shown to the user under normal conditions,
they are displayed on the operation panel only
when the defective feature is selected.
SCs that are not shown on the operation panel.
C
They are internally logged.
Turning the operation switch or main power
switch off then on resets SCs Displayed on the
D
operation panel. These are re-displayed if the
error occurs again.
SM
CÓPIA NÃO CONTROLADA
B140/B246/D052 SERIES SERVICE MODE
Definition
4-39
CÓPIA NÃO CONTROLADA
Reset Procedure
Enter SP mode, then turn the
main power switch off and
on.
Turn the main power switch
off and on.
Logging only
Turn the operation switch or
main power switch off and
on.