Ricoh B064 SERIES Service Manual page 443

Hide thumbs Also See for B064 SERIES:
Table of Contents

Advertisement

Display
42
Download Error E42
Module ID
Card No. xx/xx
43
Download Error E43
Module ID
Card No. xx/xx
44
Download Error E44
Module ID Card No.
50
No Valid Data E50
51
(no display)
52
(no display)
53
(no display)
SM
CÓPIA NÃO CONTROLADA
Details
Download result failure 3
Operation panel or language download
failed. For this error, sometimes the
message may not be displayed.
Download result failure 4
Print download failed.
Download result failure 5
The data targeted for the write
operation could not be accessed.
Download invalid
The source data for the update could
not be authenticated.
Remote ROM update failure 1
The source data for the ROM update is
corrupted because the machine is
operating and an SC code has been
issued.
Remote ROM update failure 2
The source data received for the ROM
update is corrupted; it failed a SUM
check due to its abnormal length.
Download result failure 6
The previous download in progress
was cancelled.
4-5
CÓPIA NÃO CONTROLADA
OVERVIEW
Recovery
• Cycle the machine
off/on and re-try
• Cycle the machine
off/on and re-try
• Turn the machine
power off/on.
• Set controller DIPSW-
1 to ON to force the
machine to write
• If you cannot force
the machine to write,
replace the controller
board.
• Use the correct SD
card.
• Turn the machine
power off/on and try
again.
• Try again with the
correct data.
• Do the download
procedure again.
B064 Series/B140 Series
/B246 Series/D052 Series

Advertisement

Table of Contents
loading

This manual is also suitable for:

B246 seriesB140 seriesD052 series

Table of Contents