SCANNER
3.4.2 EXPOSURE GLASS
[B]
[C]
[A]: Rear scale ( x 3)
[B]: Left cover ( x 3)
[C]: ADF exposure glass
[D]: Exposure glass
NOTE: Lift out the exposure glass and left scale together. The left scale is
permanently attached to the exposure glass with double-sided tape. Do
not remove the left scale from the exposure glass.
When re-installing the exposure glass:
• Position the exposure glass first. Make sure that the arrow (white) mark is in the
upper left corner.
• When re-installing the left cover, make sure it is seated correctly.
B064 Series/B140 Series
/B246 Series/D052 Series
CÓPIA NÃO CONTROLADA
3-12
CÓPIA NÃO CONTROLADA
[A]
[D]
B246R909.WMF
SM