B064 SERIES SERVICE MODE
SC No.
876-
The log was set for encryption
2
without the encryption module
installed:
At power on
While the machine was operating
When the log encryption setting
was changed.
876-
At power on the log encryption key
3
was disabled, causing an NVRAM
malfunction.
876-
At power on the machine attempted
4
log data encryption with the log
encryption setting disabled
(NVRAM malfunction).
-or-
At power on log encryption was
attempted with the log encryption
setting disabled (NVRAM
malfunction).
876-
Error occurred at power on.
5
Only the NVRAM was replaced with
an NVRAM from another machine.
-or-
Only the HDD was replaced with an
HDD unit from another machine.
876-
Cause unknown. The error
99
occurred at power on or while the
machine was operating.
SC900: Miscellaneous
SC No.
900
D
Electrical total counter error
The total counter contains
something that is not a number.
901
D
Mechanical total counter error
The mechanical counter is not
connected.
951
C
F-GATE signal error
When the IPU has already received
the F-GATE signal (laser writing
start trigger signal), the IPU
receives another F-GATE signal.
953
D
Scanner image setting error
The settings required for image
processing using the scanner are
not sent from the IPU.
954
D
Printer image setting error
The settings required for image
processing using the printer
controller are not sent from the IPU.
B064 Series/B140 Series
/B246 Series/D052 Series
CÓPIA NÃO CONTROLADA
Symptom
Symptom
4-32
CÓPIA NÃO CONTROLADA
Possible Cause
Install or replace and set the encryption
module.
Enable the log encryption setting.
Format the disk with SP5832-004.
Format the disk with SP5832-004.
Replace NVRAM with original NVRAM.
Replace HDD with original HDD.
If the error persists, format the HDD with
SP5832-004.
Contact Ricoh design section.
Possible Cause
• NVRAM defective
• Mechanical total counter defective
• Mechanical total counter connector not
connected
• Software defective
• BCU defective
• Software defective
• Software defective