SERVICE CALL CONDITIONS
4.2.2

SERIES SERVICE CALL CONDITIONS

There are 4 levels of service call conditions.
Level
Fusing unit SCs displayed on the operation
A
panel. The machine is disabled. The operator
cannot reset the SC.
SCs that disable only the features that use the
defective item. These SCs are not shown to the
B
operator under normal conditions. They are
displayed on the operation panel only when the
defective feature is selected.
SCs that are not shown on the operation panel.
C
They are internally logged.
Turning the operation switch (or main power
switch) off then on resets these SCs. These SCs
D
are displayed on the operation panel and
displayed again if the error reoccurs.
B234/B235/B236/D101/D102/D103
Definition
4-10
Reset Procedure
Enter SP mode, then turn the
main power switch off and on.
Turn the main power switch off
and on.
Logging only
Turn the operation switch (or
main power switch) off and on.
SM