Siemens SINUMERIK 808D ADVANCED Parameter Manual page 75

Cnc controller
Hide thumbs Also See for SINUMERIK 808D ADVANCED:
Table of Contents

Advertisement

808d-me62
-
808d-te42
-
808d-te62
-
808d-mte40
-
808d-mte60
-
Description:
Path on which the user program set with MD11620 $MN_PROG_EVENT_NAME is called in
response to an event-driven program call configured with MD20108 $MC_PROG_EVENT_MASK:
0:
1:
2:
3:
11717
D_NO_FCT_CYCLE_NAME
-
Subroutine name for D function replacement
-
-
-
Description:
Cycle name for replacement routine of the D function.
If a D function is programmed in a part program block, then, depending on machine data
MD10717 $MN_T_NO_FCT_CYCLE_NAME, MD10719 $MN_T_NO_FCT_CYCLE_MODE and MD10718
$MN_M_NO_FCT_CYCLE_PAR, the MD subprogram defined in MD11717 $MN_D_NO_FCT_CYCLE_NAME
is called.
The programmed D number can be polled in the cycle via system variable $C_D /
$C_D_PROG.
MD11717 $MN_D_NO_FCT_CYCLE_NAME is only active in Siemens mode (G290).
No more than one M/T/D function replacement can be active per part program line.
A modal subprogram call must not be programmed in the block with the D function
replacement. Furthermore, neither subprogram return nor part program end are allowed.
In the event of a conflict alarm 14016 is output.
12000
OVR_AX_IS_GRAY_CODE
-
Axis feedrate override switch Gray-coded
-
-
-
Description:
This machine data is used to adapt the axis feed override switch to the interface
coding of the PLC interface.
1:
are interpreted as a Gray code. The value which is read corresponds to a switch
setting. It is used as an index for selecting the correct override factor from the
table of MD12010 $MN_OVR_FACTOR_AX_SPEED [n].
0:
representation of the override value in percent (limit 200 percent).
Related to:
NC/PLC interface signal DB380x DBX0 (Feed override A-H), (axis-specific)
MD12010 $MN_OVR_FACTOR_AX_SPEED [n]
(Evaluation of the axis feed override switch)
12010
OVR_FACTOR_AX_SPEED
-
Evaluation of axis feedrate override switch
-
-
31
Parameter Manual
Parameter Manual, 08/2015, 6FC5397-8EP40-0BA1
2
2
2
3
3
/_N_CMA_DIR
/_N_CUS_DIR
/_N_CST_DIR
Search path in the sequence /_N_CUS_DIR, /_N_CMA_DIR, and
-
TRUE
The 5 low-order bits of the PLC interface signal DB380x DBX0 (Feed override A-H)
The feed override byte of the PLC interface is interpreted as a binary
0.00, 0.01, 0.02, 0.04,
0.06, 0.08, 0.10, 0.20...
0
3
0
3
0
3
0
3
0
3
EXP, N12, N07
STRING
-
-
EXP, N10
BOOLEAN
0
-
EXP, N10
DOUBLE
0.00
2.00
Machine data
3.2 General machine data
0/0
0/0
0/0
7/2
7/2
/_N_CST_DIR
K1
PowerOn
2/2
V1, Z1
PowerOn
1/1
V1, Z1
PowerOn
1/1
75