Siemens SINUMERIK 808D ADVANCED Parameter Manual page 127

Cnc controller
Hide thumbs Also See for SINUMERIK 808D ADVANCED:
Table of Contents

Advertisement

20115
IGNORE_REFP_LOCK_ASUP
-
Process interrupt program despite non-referenced axes
-
-
-
Description:
Despite non-referenced axes, an assigned user ASUB is processed for the interrupt
whose bit is set.
Bit 0 is assigned to interrupt 1.
Bit 1 is assigned to interrupt channel 2, etc.
Corresponds to:
MD11602 $MN_ASUP_START_MASK
MD20116 $MC_IGNORE_INHIBIT_ASUP
MD20117 $MC_IGNORE_SINGLEBLOCK_ASUP
MD20191 $MC_IGN_PROG_STATE_ASUP
MD20194 $MC_IGNORE_NONCSTART_ASUP
The machine data MD20105 $MC_PROG_EVENT_IGN_REFP_LOCK and MD20115
$MC_IGNORE_REFP_LOCK_ASUP replace bit 1 from MD11602 $MN_ASUP_START_MASK.
If MD20700 $MC_REFP_NC_START_LOCK is equal to 0, the setting in MD20105
$MC_PROG_EVENT_IGN_REFP_LOCK will be ignored.
20116
IGNORE_INHIBIT_ASUP
-
Execute interrupt program despite read-in disable
-
-
-
Description:
In spite of the set read-in disable, an assigned user ASUB is completely executed for
the interrupt channel with the set bit.
Bit 0 is assigned to interrupt channel 1.
Bit 1 is assigned to interrupt channel 2, etc.
Related to:
MD11602 $MN_ASUP_START_MASK
MD20115 $MC_IGNORE_REFP_LOCK_ASUP
MD20117 $MC_IGNORE_SINGLEBLOCK_ASUP
MD20191 $MC_IGN_PROG_STATE_ASUP
MD20194 $MC_IGNORE_NONCSTART_ASUP
20117
IGNORE_SINGLEBLOCK_ASUP
-
Execute interrupt program completely despite single block
-
-
-
Description:
In spite of the set single-block processing mode, an assigned user ASUB is completely
executed for the relevant channel with the set bit.
Bit 0 is assigned to interrupt channel 1.
Bit 1 is assigned to interrupt channel 2, etc.
The MD is only active with single block type 1.
Related to:
MD11602 $MN_ASUP_START_MASK
MD20115 $MC_IGNORE_REFP_LOCK_ASUP
MD20116 $MC_IGNORE_INHIBIT_ASUP
Parameter Manual
Parameter Manual, 08/2015, 6FC5397-8EP40-0BA1
0x200, 0x200, 0x200,
0
0x200, 0x200, 0x200,
0x200, 0x200...
0, 0, 0, 0, 0, 0, 0, 0...
0
0, 0, 0, 0, 0, 0, 0, 0...
0
3.3 Channel-specific machine data
C01
K1, Z1
DWORD
NEW CONF
0x7FFFFFFF
2/2
C01
K1, Z1
DWORD
NEW CONF
0x7FFFFFFF
2/2
C01
K1, Z1
DWORD
NEW CONF
0x7FFFFFFF
2/2
Machine data
M
M
M
127

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents