Siemens SINUMERIK 808D ADVANCED Parameter Manual page 73

Cnc controller
Hide thumbs Also See for SINUMERIK 808D ADVANCED:
Table of Contents

Advertisement

11602
ASUP_START_MASK
-
Ignore stop conditions for ASUB
-
808d-me42
-
808d-me62
-
808d-te42
-
808d-te62
-
808d-mte40
-
808d-mte60
-
Description:
This machine data defines which stop reasons are to be ignored on an ASUB start. The
ASUB is started or the following stop reasons are ignored:
Bit 0:
STOP reason: STOP key, M0 or M01
An ASUB is started immediately if NCK is in RESET status (or JOG mode) (no ASUB can be
started in RESET/JOG without this bit).
Bit 1:
Reserved! This bit was replaced by MD20105 $MC_PROG_EVENT_IGN_REFP_LOCK and MD20115
$MC_IGNORE_REFP_LOCK_ASUP.
Bit 2:
Start allowed even if a read-in disable is active; in other words, the blocks of the
ASUB program are loaded and executed immediately. This therefore disables machine data
MD20107 $MC_PROG_EVENT_IGN_INHIBIT and MD20116 $MC_IGNORE_INHIBIT_ASUP. The NCK
behavior corresponds to the machine data assignment $MC_PROG_EVENT_IGN_INHIBIT=H3F
$MC_IGNORE_INHIBIT_ASUP=HFFFFFFFF.
If the bit is not set:
The assignment of machine data MD20107 $MC_PROG_EVENT_IGN_INHIBIT and MD20116
$MC_IGNORE_INHIBIT_ASUP are evaluated.
If the particular bit in $MC_PROG_EVENT_IGN_INHIBIT or $MC_IGNORE_INHIBIT_ASUP is 0,
then although an ASUB or prog event are immediately internally initiated, the blocks
of the ASUB program are only loaded when the read-in inhibit is withdrawn.
The path is decelerated immediately when the ASUB is triggered (except with option
BLSYNC).
The read-in disable is set once more in the ASUB program.
Bit 3:
If an ASUB is started automatically from JOG, the user may stop in the middle of the
ASUB program. JOG mode is displayed continuously for the user. With bit 3 set, the user
may jog in this situation. This is not possible without bit 3. In this case, mode
change is locked with alarm 16927. By pressing the Start key, the user can continue
the ASUB program. As long as the ASUB program is running, the user is naturally not
able to jog. At the end of the ASUB program, the user may jog again.
Bit 4...15:
Corresponds with:
MD11604 $MN_ASUP_START_PRIO_LEVEL
MD20105 $MC_PROG_EVENT_IGN_REFP_LOCK
MD20107 $MC_PROG_EVENT_IGN_INHIBIT
MD20115 $MC_IGNORE_REFP_LOCK_ASUP
MD20116 $MC_IGNORE_INHIBIT_ASUP
Parameter Manual
Parameter Manual, 08/2015, 6FC5397-8EP40-0BA1
0x01
0
0x01
0
0x01
0
0x01
0
0
0
0
0
Reserved
3.2 General machine data
N01
K1, M3, TE3, TE7
DWORD
PowerOn
0xf
1/1
0xf
1/1
0xf
1/1
0xf
1/1
0xf
2/2
0xf
2/2
Machine data
73

Hide quick links:

Advertisement

Table of Contents
loading