Siemens SINUMERIK 808D ADVANCED Parameter Manual page 260

Cnc controller
Hide thumbs Also See for SINUMERIK 808D ADVANCED:
Table of Contents

Advertisement

Machine data
3.4 Axis-specific machine data
808d-me62
-
808d-te42
-
808d-te62
-
808d-mte40
-
808d-mte60
-
Description:
For incremental measuring systems:
The axis travels at this velocity between the time of synchronization with the first
zero mark and arrival at the reference point.
For linear measuring systems with distance-coded reference marks:
The axis travels at this velocity between the time of synchronization (crossing two
zero marks) and arrival at the target point.
34080
REFP_MOVE_DIST
mm, degrees
Reference point distance
-
-
1
Description:
1. Standard measuring system (incremental with equidistant zero marks)
Reference point positioning movement: 3rd phase of the reference point approach:
The axis traverses from the position at which the zero mark is detected with the
velocity REFP_AX_VELO_POS along the path REFP_MOVE_DIST + REFP_MOVE_DIST_CORR
(relative to the marker).
REFP_SET_POS is set as the current axis position at the target point.
2. Irrelevant for distance-coded measuring system.
Override switch and selection jog/continuous mode ( MD
active.
34090
REFP_MOVE_DIST_CORR
mm, degrees
Reference point offset/absolute offset
-, -
-
1
Description:
Incremental encoder with zero mark(s):
After detection of the zero mark, the axis is positioned away from the zero mark by
the distance specified in MD34080 $MA_REFP_MOVE_DIST + MD34090
$MA_REFP_MOVE_DIST_CORR. After traversing this distance, the axis has reached the
reference point. MD34100 $MA_REFP_SET_POS is transferred into the actual value.
During traversing by MD34080 $MA_REFP_MOVE_DIST + MD34090 $MA_REFP_MOVE_DIST_CORR, the
override switch and MD11300 $MN_JOG_INC_MODE_LEVELTRIGGRD (jog/continuous mode) are
active.
Distance-coded measuring system:
MD34090 $MA_REFP_MOVE_DIST_CORR acts as an absolute offset. It describes the offset
between the machine zero and the first reference mark of the measuring system.
Absolute encoder:
MD34090 $MA_REFP_MOVE_DIST_CORR acts as an absolute offset.
260
10000., 10000.,
(0./ 0.)
10000., 720., 720.
10000., 10000.,
(0./ 0.)
10000., 720.
10000., 10000.,
(0./ 0.)
10000., 720., 720., 720.
(10000.0/ 20.0),
(0./ 0.)
(10000.0/ 20.0),
(10000.0/ 20.0),
(10000.0/ 20....
(10000.0/ 20.0),
(0./ 0.)
(10000.0/ 20.0),
(10000.0/ 20.0),
(10000.0/ 20....
-2.0, -2.0
-1e15
0.0, 0.0
-1e12
(1.e300/ 1.e300)
2/2
(1.e300/ 1.e300)
2/2
(1.e300/ 1.e300)
2/2
(1.e300/ 1.e300)
2/2
(1.e300/ 1.e300)
2/2
A03, A11
G1, R1, S1, S3, G2
DOUBLE
NEW CONF
1e15
2/2
JOG_INC_MODE_IS_CONT ) are
A03, A02, A08,
G1, R1, S1, S3, G2
A11
DOUBLE
NEW CONF
1e12
2/2
Parameter Manual, 08/2015, 6FC5397-8EP40-0BA1