Siemens SINUMERIK 808D ADVANCED Parameter Manual page 310

Cnc controller
Hide thumbs Also See for SINUMERIK 808D ADVANCED:
Table of Contents

Advertisement

NC setting data
Description:
Default value for the path feed in adjustment movements of tangential axes on
activation of a tangential axis coupling during or after block search.
The content of this setting data is only used if it is not equal to zero and bit7 = 0
of MD $MN_SEARCH_RUN_MODE is set.
It is evaluated as an F-word programmed in G94.
42122
OVR_RAPID_FACTOR
%
Add. rapid traverse override can be specified through operation
-
-
-
Description:
Additional channel-specific rapid traverse override in %. The value is calculated as
a function of the OPI variable enablOvrRapidFactor on the path and during jogging of
geometry axes . The value multiplies the other overrides relevant to rapid traverse
(rapid traverse override of the machine control panel, override default through
synchronized actions $AC_OVR).
42125
SERUPRO_SYNC_MASK
-
Synchronization in approach blocks
-
808d-me42
-
808d-me62
-
808d-te42
-
808d-te62
-
808d-mte40
-
808d-mte60
-
Description:
A synchronized approach can be set for the search type SERUPRO with the setting data
SERUPRO_SYNC_MASK.
SERUPRO uses the function REPOS to move from the current machine position to the target
block of the search. A synchronization of the channels can be forced between the
reapproach block and the target block via SERUPRO_SYNC_MASK which would correspond to
the use of WAIT markers.
Note:
The user cannot program WAIT markers between reapproach block and target block in a
part program.
SERUPRO_SYNC_MASK activates this intermal WAIT marker, and defines for which other
channels this channel is to wait.
Example for channel 3:
A new block is now inserted in the Serupro approach between the reapproach block and
the target block, the function of which corresponds to the following programming:
WAITM( 101, 1,3,5,7), i.e. a WAIT marker synchronizes the channels 1, 3, 5 and 7.
The WAIT markers used internally cannot be explicitly programmed by the user.
NOTICE:
Similarly to the part program, the user can make the error of not setting the marker
in a channel, so that the other channels naturally wait for ever!
Note:
The bit mask can contain a channel that does not exist (channel gaps) without a
deadlock occurring.
Example for channel 3:
exist, so WAITM( 101, 1,3,7) is set.
310
100., 100., 100., 100.,
0.0
100., 100., 100., 100....
0, 0, 0, 0, 0, 0, 0, 0...
-
0, 0, 0, 0, 0, 0, 0, 0...
-
0, 0, 0, 0, 0, 0, 0, 0...
-
0, 0, 0, 0, 0, 0, 0, 0...
-
0, 0, 0, 0, 0, 0, 0, 0...
-
0, 0, 0, 0, 0, 0, 0, 0...
-
SD42125 $SC_SERUPRO_SYNC_MASK= 0x55
SD42125 $SC_SERUPRO_SYNC_MASK= 0x55 and channel 5 do not
-
MD12050
$MN_OVR_FACTOR_RAPID_T
RA, $AC_OVR
DOUBLE
Immediately
-
7/7
-
-
DWORD
Immediately
-
0/0
-
0/0
-
0/0
-
0/0
-
7/7
-
7/7
Parameter Manual, 08/2015, 6FC5397-8EP40-0BA1
U
S
S
S
S
U
U
Parameter Manual

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents