Machine data
3.2 General machine data
11604
ASUP_START_PRIO_LEVEL
-
Priorities from which 'ASUP_START_MASK' is effective
-
808d-me42
-
808d-me62
-
808d-te42
-
808d-te62
-
808d-mte40
-
808d-mte60
-
Description:
This machine data defines the ASUB priority from which MD11602 $MN_ASUP_START_MASK is
to be applied. MD11602 $MN_ASUP_START_MASK is applied from the level specified here up
to the highest ASUB priority level 1.
Related to:
MD11602 $MN_ASUP_START_MASK
11610
ASUP_EDITABLE
-
Activation of a user-specific ASUB program
-
-
-
Description:
This MD determines whether user-specific routine: _N_ASUP_SPF stored in directory
_N_CUS_DIR/ _N_CMA_DIR is to be used to process RET and REPOS. The user ASUB is
searched for first in _N_CUS_DIR.
Value:
0
Bit0 = 1
by the system is executed for REPOS.
Bit1 = 1
supplied by the system is executed for RET
Bit0= + bit1 = 3
Bit2 = 1
Related to:
MD11612 $MN_ASUP_EDIT_PROTECTION_LEVEL
11612
ASUP_EDIT_PROTECTION_LEVEL
-
Protection level of the user-specific ASUB program
-
-
-
Description:
Protection level of the user-specific ASUB program for RET and/or REPOS
The data is active only if MD11610 $MN_ASUP_EDITABLE is set to a value other than 0.
This machine data defines the protection level of the program _N_ASU_CUS.
MD irrelevant for:
MD11610 $MN_ASUP_EDITABLE set to 0
Related to:
MD11610 $MN_ASUP_EDITABLE
11622
PROG_EVENT_PATH
-
Call path for PROG_EVENT
-
808d-me42
-
74
7
7
7
7
0
0
0
Meaning:
Routine _N_ASUP_SPF is not activated for either RET or REPOS.
User-specific routine _N_ASUP_SPF is executed for RET, the routine supplied
User-specific routine _N_ASUP_SPF is executed for REPOS, the routine
User-specific routine _N_ASUP_SPF is executed for both RET and REPOS
User ASUB _N_ASUP_SPF is searched for first in _N_CMA_DIR
2
2
N01
DWORD
0
128
0
128
0
128
0
128
0
128
0
128
N01
DWORD
0
0x7
N01
DWORD
0
7
N01
BYTE
0
3
Parameter Manual, 08/2015, 6FC5397-8EP40-0BA1
K1, TE3, TE7
PowerOn
2/2
2/2
2/2
2/2
2/2
2/2
K1
PowerOn
2/2
K1
PowerOn
2/2
-
PowerOn
0/0