Machine data
3.2 General machine data
10719
T_NO_FCT_CYCLE_MODE
-
Setting of T function substitution
-
-
-
Description:
This machine data parameterizes the execution of the replacement subprogram for the
tool and tool offset selection.
Bit 0 = 0:
D or DL number is transferred to the replacement subprogram (default value)
Bit 0 = 1:
The D or DL number is not transferred to the replacement subprogram if the following
conditions are fulfilled: MD22550 $MC_TOOL_CHANGE_MODE = 1
or M function with which the tool change cycle is called, in a part program line.
Bit 1 = 0
Execution of the replacement subprogram at end of block (default value)
Bit 1 = 1
Execution of the replacement subprogram at block start
Bit 2 = 0:
Execution of the replacement subprogram according to the settin of bit 1
Bit 2 = 1:
Execution of the replacement subprogram at block start and at end of block.
10720
OPERATING_MODE_DEFAULT
-
Setting of mode after power ON
-
-
1
Description:
Default modes of the mode groups after power ON.
If no mode is selected by the PLC, all the channels associated with mode group n are
in the mode preset by OPERATING_MODE_DEFAULT[ n -1 ] after power ON:
0 = Automatic mode
1 = Automatic mode, submode REPOS
2 = MDI mode
3 = MDI mode, submode REPOS
5 = MDI mode, submode Reference point approach
6 = JOG mode
7 = JOG mode, submode Reference point approach
NOTICE! Depending on the machine data MD10721 $MN_OPERATING_MODE_EXTENDED, the mode
set here might not be adopted after power ON
10721
OPERATING_MODE_EXTENDED
-
Extended setting of mode after power ON
-
-
1
Description:
Extended setting of an operating mode of the operating mode groups after power on:
0 = Selection of the operating mode according to MD10720 $MN_OPERATING_MODE_DEFAULT
1 = Selection of the JOG mode if the PLC signal "Retract data available"
(DB3300.DBX4005.5) is set in at least one channel of the operating mode group
48
0
0
7, 7, 7, 7, 7, 7, 7, 7...
0
0, 0, 0, 0, 0, 0, 0, 0...
0
EXP, N12, N07
K1
DWORD
PowerOn
0x7
2/2
Programming D/DL with T
N01
H2
BYTE
PowerOn
12
1/1
N01
H2
BYTE
PowerOn
1
1/1
Parameter Manual, 08/2015, 6FC5397-8EP40-0BA1