18794
MM_TRACE_VDI_SIGNAL
-
Trace specification of VDI signals
NBUP
-
-
Description:
The NCK sends and receives PLC VDI signals. The Trace function stores the signals which
have changed in each interpolation cycle in an FIFO memory (first in-first out) having
a size of MM_MAX_TRACE_POINTS.
The FIFO is written to a file (for the 1st channel: ncsctr01.mpf) when a "trigger
event" occurs (e.g. Cancel Alarm key, see MD22704 $MC_TRACE_STOPTRACE_EVENT and
MD22700
The machine data should be interpreted as bit mask. The corresponding VDI signals are
recorded depending on which bit is set.
Bits 1.. 6 describe which axial VDI input signals are recorded in the trace
(see .. TRACE_DATA_FUNCTION).
18860
MM_MAINTENANCE_MON
-
Activation of maintenance data recording
-
808d-me42
-
808d-me62
-
808d-te42
-
808d-te62
-
808d-mte40
-
808d-mte60
-
Description:
Maintenance data is recorded when this MD has the value TRUE.
The axial MD33060 $MA_MAINTENANCE_DATA sets which data are to be recorded.
Details are to be found in the service documentation.
18866
MM_NUM_KIN_TRAFOS
-
Maximum number of transformations that can be defined by
kinematic chains.
-
808d-me42
-
808d-me62
-
808d-te42
-
808d-te62
-
808d-mte40
-
808d-mte60
-
Description:
This machine data defines the maximum number of transformations in the NCK that can be
defined by kinematic chains.
It also defines the number of data blocks ($NT_...[1] to $NT_...
[$MN_MM_NUM_KIN_TRAFOS] available for parameterizing these transformations. The data
record with index 0 is locked.)
The kinematic transformations conventionally parameterized in machine data can exist
irrespective of this.
18960
POS_DYN_MODE
-
Type of positioning axis dynamic response
-
-
-
Parameter Manual
Parameter Manual, 08/2015, 6FC5397-8EP40-0BA1
0
$MC_TRACE_STARTTRACE_EVENT).
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
0
0
0
0
0
0
0
EXP, N02, N06
DWORD
0
0x7FFFFFFF
EXP, N01
BOOLEAN
0
-
0
-
0
-
0
-
0
-
0
-
N02, N09
DWORD
0
200
0
200
0
200
0
200
0
200
0
200
N01
BYTE
0
1
Machine data
3.2 General machine data
-
PowerOn
1/1
W6
PowerOn
7/2
7/2
7/2
7/2
0/0
0/0
W1
PowerOn
7/2
7/2
7/2
7/2
0/0
0/0
K1
Reset
1/1