Siemens SINUMERIK 808D ADVANCED Parameter Manual page 297

Cnc controller
Hide thumbs Also See for SINUMERIK 808D ADVANCED:
Table of Contents

Advertisement

Description:
Actual value difference between master axis and slave axis in the case of alarm 10653.
Leads to alarm 10657 after Power ON.
37140
GANTRY_BREAK_UP
-
Invalidate gantry axis grouping
CTEQ
808d-me42
-
808d-me62
-
808d-te42
-
808d-te62
-
808d-mte40
-
808d-mte60
-
Description:
GANTRY_BREAK_UP = "0"
The forced coupling of the gantry axis grouping remains valid! Monitoring of violation
of the gantry warning or trip limit is active!
GANTRY_BREAK_UP = "1"
This breaks up the forced coupling of the gantry grouping, thus allowing all gantry
axes in this grouping to be traversed individually in JOG, AUTOMATIC, and MDI modes.
Monitoring for violation of the gantry warning or trip limit is deactivated! The NC/
PLC interface signal DB390x DBX5005.5 "gantry grouping is synchronized" is set to "0".
Notice:
In cases where the gantry axes continue to be mechanically coupled, the machine may
sustain damage in this operating state when the leading or synchronized axis is
traversed!
The gantry axes cannot be referenced individually.
Corresponds with:
MD 37100: $MA_GANTRY_AXIS_TYPE Gantry axis definition
MD 37110: $MA_GANTRY_POS_TOL_WARNING Gantry warning limit
MD 37130: $MA_GANTRY_POS_TOL_REF
NC/PLC interface signal DB390x DBX5005.5 (gantry grouping is synchronized)
NC/PLC interface signal DB390x DBX5005.2 (gantry trip limit exceeded)
37150
GANTRY_FUNCTION_MASK
-
Gantry functions
-
808d-me42
-
808d-me62
-
808d-te42
-
808d-te62
-
808d-mte40
-
808d-mte60
-
Description:
Special gantry functions are set with this MD.
The MD is bit-coded, the following bits are assigned:
Bit 0 == 0:
Extended monitoring of the actual value difference is inactive.
An offset between master and slave axes occurring in tracking or BREAK_UP is not taken
into account in the monitoring of the actual value difference.
Alarm 10657 is not output if alarm 10563 occurs before Power OFF.
Bit 0 = 1:
Parameter Manual
Parameter Manual, 08/2015, 6FC5397-8EP40-0BA1
FALSE
FALSE
FALSE
FALSE
FALSE
FALSE
Gantry trip limit during referencing
0x00
0x00
0x00
0x00
0x00
0x00
EXP, A01, A10
BOOLEAN
0
-
0
-
0
-
0
-
0
-
0
-
A10
DWORD
0
0x7
0
0x7
0
0x7
0
0x7
0
0x7
0
0x7
Machine data
3.4 Axis-specific machine data
G1, Z3
Reset
ReadOnly
1/1
ReadOnly
1/1
7/2
7/2
-
Reset
ReadOnly
1/1
ReadOnly
1/1
7/2
7/2
297

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents