Detailed descriptions of interface signals
5.7 Channel-specific signals
Application
corresponding to ...
Note for the reader
DB3200
DBX6.2
Edge evaluation: No
Signal state 1 or edge
change 0 → 1
Signal state 0 or edge
change 1 → 0
Signal irrelevant for ...
Application example
382
In a case there an auxiliary function has to have been executed before the
next block can be processed (e.g. for a tool change), automatic block change
must be inhibited with read-in disable.
IS "Program status running"
Function Manual Basic Functions K1
Delete distance-to-go
Signal(s) to channel (PLC → NCK)
Signal(s) updated: Cyclic
IS "Delete distance-to-go" for path axes is only active in AUTOMATIC mode.
The rising edge of the interface signal is only effective for the axes involved
in the geometry grouping. These are also stopped with a ramp stop and their
distance-to-go deleted (setpoint - actual value difference). Any remaining fol‐
lowing error is still removed. The next program block is then started.
Remark:
IS "Delete distance-to-go" does not influence the running dwell time in a pro‐
gram block with dwell time.
No effect
Positioning axes
Terminating motion because of an external signal (e.g. probe)