Siemens SINUMERIK 808D ADVANCED Parameter Manual page 64

Cnc controller
Hide thumbs Also See for SINUMERIK 808D ADVANCED:
Table of Contents

Advertisement

Machine data
3.2 General machine data
Active: The change in the data becomes active on the start of the upload for the next
range.
The settings are only active, if MD11212 $MN_UPLOAD_CHANGES_ONLY=FALSE.
11212
UPLOAD_CHANGES_ONLY
-
Data backup type for an active file system.
-
-
-
Description:
Only values of the selected file of the active file system
that deviate from the default setting are backed up.
TRUE
from the standard setting are backed up (a differential data backup)
FALSE = all values of the selected file of the active file system are backed up.
setting is active.
11240
PROFIBUS_SDB_NUMBER
-
SDB number
-
808d-me42
4
808d-me62
4
808d-te42
4
808d-te62
4
808d-mte40
4
808d-mte60
4
Description:
Number of the system data block (SDB) used for configuring the I/Os.
The following assignments of MD11240[0,1,2,3] are prmitted:
[0, -1, 0, 0] telegram 136 and axis extension NX10.3
[1, -1, 1, 1] telegram 136 and axis extension NX15.3 (= default)
[2, -1, 2, 2] telegram 136 and axis extension NX15.3, 1x CU320-2 PN (only PPU 26x.3/28x.
3)
[3, -1, 3, 3] telegram 116 and axis extension NX10.3
[4, -1, 4, 4] telegram 136 and axis extension NX15.3, 1x CU310-2 PN (only PPU 26x.3/28x.
3)
[5, -1, 5, 5] telegram 136 and axis extension NX15.3, 2x CU310-2 PN (only PPU 26x.3/28x.
3)
11294
SIEM_TRACEFILES_CONFIG
-
Configuration of the SIEM* trace file
-
-
-
Description:
Configuration of the tracefiles SIEM*
Bit0:
Additional information about the PDUs sent is to be entered in _N_SIEMDOMAINSEQ_MPF
for download
Bit1:
Additional information about the PDUs received is to be entered in
_N_SIEMDOMAINSEQ_MPF for download
64
TRUE
= only the values of the selected file of the active file system that deviate
The value of MD11210 $MN_UPLOAD_MD_CHANGES_ONLY than has no effect.
Same significance as MD11210 $MN_UPLOAD_MD_CHANGES_ONLY=0.
However, if MD11210 $MN_UPLOAD_MD_CHANGES_ONLY is not equal to 0, then this
-1, -1, -1, -1
0, -1, -1, -1
-1, -1, -1, -1
0, -1, -1, -1
-1, -1, -1, -1
0, -1, -1, -1
0
N01, N05
BOOLEAN
-
-
N01, N05
DWORD
-1, -1, -1, -1
7, 7, 7, 7
-1, -1, -1, -1
7, 7, 7, 7
-1, -1, -1, -1
7, 7, 7, 7
-1, -1, -1, -1
7, 7, 7, 7
-1, -1, -1, -1
7, 7, 7, 7
-1, -1, -1, -1
7, 7, 7, 7
EXP
DWORD
0
0x7FFFFFFF
Parameter Manual, 08/2015, 6FC5397-8EP40-0BA1
-
Immediately
2/2
K4, FBU
PowerOn
2/2
2/2
2/2
2/2
2/2
2/2
-
PowerOn
1/1
Parameter Manual

Hide quick links:

Advertisement

Table of Contents
loading