Detailed descriptions of interface signals
5.3 Signals from / to HMI
Signal state 0
corresponding to ...
Note for the reader
DB1700
DBX1.3
Edge evaluation: No
Signal state 1
Signal state 0
Application
Note for the reader
DB1700
DBX1.7
Edge evaluation: No
Signal state 1
Signal state 0
corresponding to ...
Note for the reader
DB1700
DBX2.0 to 3.1
Edge evaluation: No
Signal state 1
Signal state 0
corresponding to ...
Note for the reader
358
Dry run feedrate is not selected.
The programmed feedrate is active.
IS "Activate dry run feedrate" (DB3200 DBX0.6)
SD: DRY_RUN_FEED (dry run feedrate)
Function Manual Basic Functions V1, K1
Feedrate override selected for rapid traverse
Signal(s) to channel (HMI → PLC)
Signal(s) updated: Cyclic
The feedrate override switch should also be active as rapid traverse override
switch.
Override values above 100% are limited to the maximum value for 100%
rapid traverse override.
The IS "Feedrate override for rapid traverse selected" is automatically en‐
tered from the operator panel into the PLC interface and is transferred from
the basic PLC program to the PLC interface signal "Rapid traverse override
active".
Further, the IS "Feedrate override" (DB3200 DBB4) is copied from the
basic PLC program into the IS "Rapid traverse override" (DB3200 DBB5).
The feedrate override switch should not be activated as rapid traverse over‐
ride switch.
The signal is used when no separate rapid traverse override switch is avail‐
able.
Function Manual Basic Functions V1
Program test selected
Signal(s) from HMI → PLC
Signal(s) updated: Cyclic
Program control program test has been selected from the operator interface.
This does not activate the function.
Program control program test has not been selected from the operator inter‐
face.
IS "Activate program test"
IS "Program test active"
Function Manual Basic Functions V1
Skip block selected
Signal(s) from HMI → PLC
Signal(s) updated: Cyclic
Program control – skip block – has been selected from the operator interface.
This does not activate the function.
Program control – skip block – has not been selected from the operator in‐
terface.
IS "Activate skip block"
Function Manual Basic Functions K1
Parameter Manual, 08/2015, 6FC5397-8EP40-0BA1
Parameter Manual