This variant is justified for programming "Tool number=Location" (revolver as
toolholder) without tool management. The revolver can now be positioned on a location
for which a tool has not (yet) been defined.
This bit has no meaning if bit 0=1 is set.
Bit 8=0: A tool that is located at a blocked magazine location is not taken into
account when selecting a tool. (default setting)
Bit 8=1: Even a tool that is located at a blocked magazine location is taken into
account when selecting a tool (this corresponds to the previous behavior.)
22620
START_MODE_MASK_PRT
-
Initial setting on special starts
-
-
-
Description:
This machine data is activated via MD22621 $MC_ENABLE_START_MODE_MASK_PRT.
If MD22621 $MC_ENABLE_START_MODE_MASK_PRT is in its initial setting, MD22620
$MC_START_MODE_MASK_PRT is inactive.
If MD22620 $MC_START_MODE_MASK_PRT is activated for "search via program test" (abbr.
SERUPRO), then MD22620 $MC_START_MODE_MASK_PRT replaces MD20112 $MC_START_MODE_MASK
when "search via program test" is started.
This enables a behavior deviating from PLC start to be set at the start of the search.
The meaning of the bit-by-bit assignment of MD22620 $MC_START_MODE_MASK_PRT is the
same as that in MD20112 $MC_START_MODE_MASK.
22621
ENABLE_START_MODE_MASK_PRT
-
Enables MD22620 $MC_START_MODE_MASK_PRT
-
-
-
Description:
MD22620 $MC_START_MODE_MASK_PRT is activated via MD22621
$MC_ENABLE_START_MODE_MASK_PRT.
If MD22621 $MC_ENABLE_START_MODE_MASK_PRT is in its initial setting, MD22620
$MC_START_MODE_MASK_PRT is inactive.
Bit0 =
If a "search via program test" (English abbr. SERUPRO) is started from RESET (PI
service _N_FINDBL mode paramter == 5), MD22620 $MC_START_MODE_MASK_PRT replaces
MD20112 $MC_START_MODE_MASK.
This method can be used to set a start behavior differing from PLC start when the
search is started.
22700
TRACE_STARTTRACE_EVENT
-
Diagnostic data rec. starts with event
TRACE_STARTTRACE_EVENT.
NBUP
-
-
Description:
The machine data is intended for diagnostics.
The recording of the diagnostic data does not start until the event
(TRACE_STARTTRACE_EVENT) has occurred at the trace point
(TRACE_STARTTRACE_TRACEPOINT) and in the correct step (TRACE_STARTTRACE_STEP)!
The machine data is additionally activated using the Cancel alarm key.
Parameter Manual
Parameter Manual, 08/2015, 6FC5397-8EP40-0BA1
0x400, 0x400, 0x400,
0x400, 0x400, 0x400,
0x400, 0x400...
0x0, 0x0, 0x0, 0x0,
0x0, 0x0, 0x0, 0x0...
1:
-
3.3 Channel-specific machine data
EXP, C03
DWORD
0
0xFFFF
EXP, C03
DWORD
0
0x1
EXP, C06
STRING
-
-
Machine data
M3, K1
Reset
1/1
M
M3, K1
Reset
1/1
M
-
PowerOn
1/1
M