Siemens SINUMERIK 808D ADVANCED Parameter Manual page 373

Cnc controller
Hide thumbs Also See for SINUMERIK 808D ADVANCED:
Table of Contents

Advertisement

Signal irrelevant for ...
Note for the reader
DB3000
DBX1.6
Edge evaluation: No
Signal state 1 or edge
change 0 → 1
Signal state 0 or edge
change 1 → 0
corresponding to ...
Note for the reader
DB3000
DBX1.7
Edge evaluation: No
Signal state 1 or edge
change 0 → 1
Signal state 0 or edge
change 1 → 0
corresponding to ...
Note for the reader
DB3000
DBX2.0 to .6
Edge evaluation: No
Parameter Manual
Parameter Manual, 08/2015, 6FC5397-8EP40-0BA1
if JOG mode is not active.
Function Manual Basic Functions K1
Single block type B
Signal(s) updated:
Bit set and DB3000 DBX1.7 not set: Response across mode groups
● Channel is stopped.
● Channel receives a start command.
● Channel KS stops at the end of the block.
(If DB3000 DBX1.6 and DB3000 DBX1.7 are set simultaneously, it is impos‐
sible to determine which single block type is required. The control then as‐
sumes: No single block across mode groups.)
If bit DB3000 DBX1.6 is not set and bit DB3000 DBX1.7 is set, then it is single
block type A.
(If DB3000 DBX1.6 and DB3000 DBX1.7 are not set, it is impossible to de‐
termine which single block type is required. The control then assumes: No
single block across mode groups).
Single block type A
Single block type A
Signal(s) updated:
DB3000 DBX1.7 set and DB3000 DBX1.6 not set: Response across modes
● Channel is stopped.
● Channel receives a start command.
● Channel KS stops at the end of the block.
(If DB3000 DBX1.6 and DB3000 DBX1.7 are set simultaneously, it is impos‐
sible to determine which single block type is required. The control then as‐
sumes: No single block access across modes).
If DB3000 DBX1.7 is not set and DB3000 DBX1.6 is set, then it is single block
type B.
(If DB3000 DBX1.6 and DB3000 DBX1.7 are not set, it is impossible to de‐
termine which single block type is required. The control then assumes: No
single block access across modes).
Single block type B
Machine function 1 INC, 10 INC, 100 INC, 1000 INC, 10000 INC, var. INC,
continuous
Signal(s) to modes (PLC → NCK)
Signal(s) updated: Cyclic
Detailed descriptions of interface signals
5.6 Mode signals
373

Hide quick links:

Advertisement

Table of Contents
loading