Par. No.
Name
r0037[0...1
Servo drive temperatures
9]
Description: Displays the temperatures in the servo drive.
● [0] = Inverter, maximum value
● [1] = Depletion layer maximum value
● [2] = Rectifier maximum value
● [3] = Air intake
● [4] = Interior of servo drive
● [5] = Inverter 1
● [6] = Inverter 2
● [7] = Inverter 3
● [8] = Inverter 4
● [9] = Inverter 5
● [10] = Inverter 6
● [11] = Rectifier 1
● [12] = Rectifier 2
● [13] = Depletion layer 1
● [14] = Depletion layer 2
● [15] = Depletion layer 3
● [16] = Depletion layer 4
● [17] = Depletion layer 5
● [18] = Depletion layer 6
● [19] = Cooling system liquid intake
The value of -200 indicates that there is no measuring signal.
● r0037[0]: Maximum value of the inverter temperatures (r0037[5...10]).
● r0037[1]: Maximum value of the depletion layer temperatures (r0037[13...18]).
● r0037[2]: Maximum value of the rectifier temperatures (r0037[11...12]).
The maximum value is the temperature of the hottest inverter, depletion layer, or rectifier.
r0068
Absolute current actual value
Description: Displays actual absolute current.
For A_INF, S_INF the following applies:
● The value is updated with the current controller sampling time.
The following applies for SERVO:
● The value is updated with a sampling time of 1 ms.
● Absolute current value = sqrt(Iq^2 + Id^2)
● The absolute current actual value is available smoothed (r0027) and unsmoothed (r0068).
Dependency: r0027
Parameter Manual
Parameter Manual, 08/2015, 6FC5397-8EP40-0BA1
Min
Max
Factory
setting
-
-
-
-
-
-
SINAMICS V70 parameters
7.2 V70 parameters on BOP
Unit
Data type
Effective
°C
Float
-
Arms
Float
-
Can be
changed
-
-
489