MD18660 $MN_MM_NUM_SYNACT_GUD_REAL[1] =
MD18660 $MN_MM_NUM_SYNACT_GUD_REAL[2] =
MD18660 $MN_MM_NUM_SYNACT_GUD_REAL[3] =
MD18660 $MN_MM_NUM_SYNACT_GUD_REAL[8] =
In each case, fields with the following properties are created:
Data type REAL
Field size corresponding to <value> of the relevant machine data
Predefined names:
SYG_RS[ ] -> Synact parameter of type REAL in the SGUD block
SYG_RM[ ] -> Synact parameter of type REAL in the MGUD block
SYG_RU[ ] -> Synact parameter of type REAL in the UGUD block
SYG_R4[ ] -> Synact parameter of type REAL in the GUD4 block
....
SYG_R9[ ] -> Synact parameter of type REAL in the GUD9 block
The parameters can be read and written both by the part program and also via
synchronous actions.
18661
MM_NUM_SYNACT_GUD_INT
-
Number of configurable GUD variables of type integer
-
808d-me42
1
808d-me62
1
808d-te42
1
808d-te62
1
808d-mte40
9
808d-mte60
9
Description:
The MD18661 $MN_MM_NUM_SYNACT_GUD_INT[ ] can be used to extend individual GUD blocks
by additional channel-specific parameter areas of type INTEGER. The GUD blocks are
differentiated by the field index:
MD18661 $MN_MM_NUM_SYNACT_GUD_INT[0] = <value> -> extension of the SGUD block
MD18661 $MN_MM_NUM_SYNACT_GUD_INT[1] =
MD18661 $MN_MM_NUM_SYNACT_GUD_INT[2] =
MD18661 $MN_MM_NUM_SYNACT_GUD_INT[3] =
MD18661 $MN_MM_NUM_SYNACT_GUD_INT[8] =
In each case, fields with the following properties are created:
Data type BOOL
Field size corresponding to <value> of the relevant machine data
Predefined names:
SYG_IS[ ] -> Synact parameter of type INT in the SGUD block
SYG_IM[ ] -> Synact parameter of type INT in the MGUD block
SYG_IU[ ] -> Synact parameter of type INT in the UGUD block
SYG_I4[ ] -> Synact parameter of type INT in the GUD4 block
....
SYG_I9[ ] -> Synact parameter of type INT in the GUD9 block
The parameters can be read and written both by the part program and also via
synchronous actions.
Parameter Manual
Parameter Manual, 08/2015, 6FC5397-8EP40-0BA1
0, 0, 0, 0, 0, 0, 0, 0...
0
0, 0, 0, 0, 0, 0, 0, 0...
0
0, 0, 0, 0, 0, 0, 0, 0...
0
0, 0, 0, 0, 0, 0, 0, 0...
0
0, 0, 0, 0, 0, 0, 0, 0...
0
0, 0, 0, 0, 0, 0, 0, 0...
0
<value> -> extension of the MGUD block
<value> -> extension of the UGUD block
<value> -> extension of the GUD4 block
<value> -> extension of the GUD9 block
N02
-
DWORD
PowerOn
32767
0/0
32767
0/0
32767
0/0
32767
0/0
32767
7/2
32767
7/2
<value> -> extension of the MGUD block
<value> -> extension of the UGUD block
<value> -> extension of the GUD4 block
<value> -> extension of the GUD9 block
Machine data
3.2 General machine data