If the drift additional value exceeds the limit value entered in MD36710
$MA_DRIFT_LIMIT, alarm 25070 "Drift value too large" is output and the drift
additional value is limited to this value.
Not relevant for:
MD36700 $MA_DRIFT_ENABLE = 0
36720
DRIFT_VALUE
%
Basic drift value
-
-
1
Description:
Only for special analog and hydraulic drives (not active with PROFIdrive drives):
The value entered in MD36720 $MA_DRIFT_VALUE is always added as an offset to the
manipulated variable. Whereas automatic drift compensation is active only for position-
controlled axes, this machine data is always active.
Special case: the following applies to PROFIdrive drives:
This MD can also be used for "simple" drives that have drift problems due to drive-
internal implementation as analog drives. To avoid erroneous settings, this static
drift compensation only becomes active with PROFIdrive if MD32250 $MA_RATED_OUTVAL !=
0 (i.e. the MD has no effect in the case of automatic interface adjustment between the
NC and the drive).
Note:
Drift compensation must not be active if the DSC function (MD32640
$MA_STIFFNESS_CONTROL_ENABLE=1) is being used, otherwise unexpected speed
oscillations will occur when DSC is enabled/disabled.
Standardization: The input value is related to the corresponding interface
standardization in
MD32250 $MA_RATED_OUTVAL,
MD32260 $MA_RATED_VELO, and
MD36210 $MA_CTRLOUT_LIMIT.
36730
DRIVE_SIGNAL_TRACKING
-
Acquisition of additional drive actual values
-
808d-me42
-
808d-me62
-
808d-te42
-
808d-te62
-
808d-mte40
-
808d-mte60
-
Description:
MD36730 $MA_DRIVE_SIGNAL_TRACKING = 1 activates the acquisition of the following drive
actual values (if they are made available by the drive):
$AA_LOAD
$AA_POWER
$AA_TORQUE Drive torque setpoint
$AA_CURR
MD36730 $MA_DRIVE_SIGNAL_TRACKING = 2 activates the acquisition of the following drive
actual values:
With PROFIdrive, it must be ensured that the stated values are also transmitted in the
drive actual message frame (provide sufficient message frame length on the bus, assign
the values to the message frame content in the drive, e.g. use message frame 116).
$VA_DP_ACT_TEL shows actual value message frame words
Note: Values 3 and 4 are reserved
Parameter Manual
Parameter Manual, 08/2015, 6FC5397-8EP40-0BA1
0.0
-1e15
0
0
1
0
0
0
1
0
0
0
0
0
Drive load
Drive active power
Smoothed current setpoint (q-axis current) of drive
3.4 Axis-specific machine data
EXP, A07, A09
-
DOUBLE
NEW CONF
1e15
1/1
A10
B3
BYTE
PowerOn
4
0/0
1
1/1
4
0/0
1
1/1
4
7/2
4
7/2
Machine data
293