MD20060 $MC_AXCONF_GEOAX_NAME_TAB (geometry axis name in the channel [GEOAxisno.]
MD20080 $MC_AXCONF_CHANAX_NAME_TAB (channel axis name in the channel [Channelaxisno.]
10050
SYSCLOCK_CYCLE_TIME
s
System clock cycle
SFCO
808d-me42
-
808d-me62
-
808d-te42
-
808d-te62
-
808d-mte40
-
808d-mte60
-
Description:
Basic cycle time of the system software
The cycle time settings of cyclical tasks (position controller/IPO) are multiples of
this basic cycle.
For PROFIBUS/PROFINET:
In the case of systems with a PROFIBUS DP connection, this MD corresponds to the
PROFIBUS DP cycle time. This time is read from the configuration file (SDB-Type-2000)
during startup and written to the MD.
This MD can only be changed via the configuration file.
Note:
Reducing this MD can result in an automatic correction of
MD10064 $MN_POSCTRL_CYCLE_DESVAL_DELAY
that cannot be undone by a subsequent increase!
Details:
The basic cycle is incremented in multiples of units of the measured value sampling
cycle. When the system powers up, the entered value is automatically rounded to a
multiple of this incrementation.
Note:
Discrete timer division ratios can give rise to the entered value producing a value
that is not an integer after a Power OFF/ON.
For example:
Input
Input
10064
POSCTRL_CYCLE_DESVAL_DELAY
s
Clock skew of the DMA for the setpoints
-
808d-me42
-
808d-me62
-
808d-te42
-
808d-te62
-
808d-mte40
-
808d-mte60
-
Description:
For SINAMICS-Integrated only:
Only relevant to operation with SINAMICS-Integrated drives on SOC modules.
Offset of the output of the setpoints via DMA in relation to the PROFIBUS DP cycle.
Parameter Manual
Parameter Manual, 08/2015, 6FC5397-8EP40-0BA1
0.002
0.001
0.004
0.001
0.002
0.001
0.004
0.001
0.002
0.001
0.004
0.001
=0.005s
after power OFF/ON
or
=0.006s
after power OFF/ON
0.0
0.000
0.0
0.000
0.0
0.000
0.0
0.000
0.0
0.000
0.0
0.000
3.2 General machine data
N01, N05, N11
G3, G2, R1
DOUBLE
PowerOn
0.008
0/0
0.008
0/0
0.008
0/0
0.008
0/0
0.008
7/2
0.008
7/2
=0.00499840
=0.0060032
N01, N05
G3
DOUBLE
PowerOn
0.008
ReadOnly
0.008
ReadOnly
0.008
ReadOnly
0.008
ReadOnly
0.008
7/2
0.008
7/2
Machine data