Machine data
3.2 General machine data
Value
0:
format. This mode maps decimal numbers inaccurately if this format's 52-bit wide
mantissa is inadequate to map the number in binary notation. To solve this problem,
all comparison commands ( ==, <>, >=, <=, > and < ) are checked for relative equality
of 1E-12.
comparisons by setting bit 0. (Compatibility setting for software releases earlier
than SW 6.4)
1:
can be programmed in the part program. The channel name can thus also be programmed
instead of a numerical value for the channel number in programming coordination
commands such as (START(), INIT(), WAIT() etc.
2:
3:
is activated. This means that all invalid ASCII characters in a part program block are
internally handled as blank.
4:
of an Ipo cycle.
10284
DISPLAY_FUNCTION_MASK
-
Behavior of various display variables
-
-
-
Description:
Bit mask for parameterizing various display variables:
BitNo.
Bit0:
Parameters are assigned to the OPI variable lastBlockNoStr in the SPARP and SPARPP
blocks.
Bit1:
Concerns the OPI variable cmdSpeed in the SPARPP block. If the bit is set, the variable
returns the programmed speed even if the spindle is at a standstill or in another mode
(positioning mode, axis mode).
Bit2
Concerns the OPI variable cmdSpeed in the SPARPP block. (reserved for constant cutting
speed)
Bit8:
Servotrace manages larger numerical values internally. Overruns in data format are
avoided. The accuracy may be reduced with large numerical values.
10368
HW_ASSIGN_DIG_FASTOUT
-
Hardware assignment of external digital NCK outputs
-
-
4
38
0x1
Comparison commands ">" and "<" are processed as for SW 6.3 and earlier:
Sub-program data of the type REAL are mapped internally in the IEEE 64 bit
This procedure is deactivated for greater than (>) and less than ( < )
0x2
Programming the channel names from machine data MD20000 $MC_CHAN_NAME
By setting bit 1, the channel name stored in machine data MD20000 $MC_CHAN_NAME
0x4
reserved
0x8
Convert illegal ASCII characters into blanks
By setting bit3, the previous behavior when interpreting a part program block
0x10
The wait time G4 F<wait time> is rounded off as a multiple integer
This means that a G4 F0.001 only takes one cycle, for an Ipo cycle of 1 msec.
0x0
Hexadec.
Meaning with bit set
value
0x1
0x2
0x4
0x100
0x01000000,
0x01000000,
0x01000000,
0x01000000,
0x01000000, 0x01...
EXP, N01
DWORD
0
0x7FFFFFFF
N10
DWORD
0x01000000
0x060003FF
Parameter Manual, 08/2015, 6FC5397-8EP40-0BA1
-