NC setting data
808d-mte40
-
808d-mte60
-
Description:
Bit mask:
Bit no.
------------------------------------------------------------------------------
0(LSB)-1
switched off
------------------------------------------------------------------------------
2
------------------------------------------------------------------------------
3
------------------------------------------------------------------------------
4
------------------------------------------------------------------------------
5
------------------------------------------------------------------------------
6
------------------------------------------------------------------------------
7
------------------------------------------------------------------------------
8
------------------------------------------------------------------------------
9
------------------------------------------------------------------------------
Application example(s)
NC language:
Related to ....
43780
OSCILL_IS_ACTIVE
-
Activate oscillation movement
-
808d-me42
-
808d-me62
-
350
0
0
| Meaning in OSCILL_CTRL_MASK
| 0: Stop at the next reversal point if the
|
oscillating movement is switched off
|
| 1: Stop at reversal point 1 if the
|
oscillating movement is switched off
| 2: Stop at reversal point 2 if the
|
oscillating movement is switched off
| 3: Do not approach a reversal point when the oscillating movement is
|
if no sparking-out strokes are programmed
| 1: Approach end position after sparking out
| 1: If the oscillating movement is canceled by delete distance-to-go,
|
then the sparking-out strokes are to be executed afterwards
|
and the end position approached if necessary
| 1: If the oscillating movement is canceled by delete distance-to-go,
|
then the corresponding reversal point
|
is approached on switch off
| 1: Changed feedrate does not become active until the next reversal point
| 1: Path override is active if the feed rate is 0,
|
otherwise speed override is active
| 1: In the case of rotary axes DC (shortest path)
| 1: Execute sparking-out stroke as single stroke not as double stroke
| 1: On starting, first approach the starting position, see
|
SD43790 $SA_OSCILL_START_POS
OSCTRL[Axis]=(setting options, reset options)
MD10709 $MN_PROG_SD_POWERON_INIT_TAB
MD10710 $MN_PROG_SD_RESET_SAVE_TAB
FALSE
FALSE
0
0x7FFFFFFF
0
0x7FFFFFFF
-
BOOLEAN
0
-
0
-
Parameter Manual, 08/2015, 6FC5397-8EP40-0BA1