Predefined Properties Parameters
Following are the parameters you can fill when predefining an endpoint:
Unit Type – The type of unit you are defining. The unit types you can choose from include
Terminal, Gateway, MCU and Undefined. The Gatekeeper allows dynamic registration of a
predefined endpoint only when it corresponds to the Unit Type you set. If you are not sure
what type of endpoint you are predefining, choose Undefined.
Max. Distance – The logical distance outside this zone that the Gatekeeper allows this
endpoint to call. For details on setting the distance parameters, see "Distance Settings," page
6-32.
Registration IP – This is the address through which the endpoint receives Registration
Admission Status (RAS) messages from the Gatekeeper. This field must be filled.
Port – This is the port number for this H.323 endpoint. The IP address together with the
port number form the socket that is the communication link between the endpoint and the
Gatekeeper. If this is the only endpoint running on the terminal you can leave the port
number set to zero. If two or more endpoints are running on the same terminal, you must
enter a different number for each port.
Terminal IDs and Phone Numbers – These are the aliases you assign to the endpoint. You
can enter up to five different IDs and five different Phone Numbers. Aliases should be
unique for endpoints in a zone, unless Zone Prefixes are defined. For details on setting Zone
Prefixes, see "Defining Gatekeeper Built-in Services," page 6-2. Additional phone numbers
can be identical.
Allowed Services – Opens the Allowed Services screen where you can determine which of
the services defined for the Gatekeeper the endpoint can access.
Defining the Properties of a New Endpoint
#"
To define properties for a new endpoint
1. Select the type of endpoint you are adding from the Unit Type drop down list.
2. Enter the Max. Distance if you want to set distance limitations in a multiple zone
environment for this endpoint. Valid values are between 0 and 255.
3. If the endpoint you are defining cannot register dynamically with the Gatekeeper,
select the Online Always check box.
4. Enter the IP address of the endpoint in the Registration IP field.
5. Enter the port number of the endpoint in the Port field if necessary.
6. Enter the IDs and phone numbers you want to assign to this endpoint in the
corresponding fields.
If the endpoint supports dynamic registration, you have to enable the Gatekeeper to add the
predefined properties to the registration data. Otherwise, no calls are forwarded to the