Mode No.
2-001
Drum Charge
Voltage
Adjustment (for
copying) †
2-002-001
Drum Charge
to
Voltage Display
2-002-002
2-003
Drum Charge
Voltage
Adjustment (for
making V
SP
patterns) †
2-101-001
Leading/Trailing
Edge Erase
to
2-101-002
Margin
Adjustment †
2-201-001 Development
Bias
Adjustment (for
copying) †
2-201-002 Lightest ID
Level
Development
Bias
Adjustment †
2-203
Development
Bias
Adjustment (for
making V
SP
patterns) †
FSM
Function
Adjusts the voltage applied to the drum charge
roller during copying.
The adjustment factor set with this SP mode is
added to the base voltage.
(30 V per step [Range: Base voltage - 480 V
to Base voltage + 480 V]
Displays the voltage applied to the drum
charge roller.
SP2-002-001: For copying
SP2-002-002: For making V
The first three digits are displayed in the
reduce/enlarge indicator. The actual value is
the displayed value x (–10) V.
Just after the main switch is turned on, the
initial setting voltage is displayed.
After one or more copies, the actual applied
voltage (including the process control
corrections) is displayed.
Adjusts the voltage applied to the drum charge
roller when making V
patterns.
SP
The adjustment factor set with this SP mode is
added to the base voltage.
(10 V per step [Range: Base voltage –160 V
to Base voltage + 160 V]
Adjusts the leading and trailing edge erase
margins.
SP2-101-001: Leading edge erase margin
SP2-101-002: Trailing edge erase margin
(0.5 mm per step [range: 0.0 mm to +16.0
mm])
Adjusts the development bias for copying to
make copies lighter or darker in general.
The adjustment factor set with this SP mode is
applied to the base voltage.
(20 V per step [Range: Base voltage –80 V to
Base voltage +80 V])
Adjusts the development bias for manual ID
level 7.
The adjustment factor set with this SP mode is
applied to the base voltage when ID level 7 is
selected.
Adjusts the development bias for making V
patterns
The adjustment factor set with this SP mode is
added to the base voltage.
(20 V per step [Range: Base voltage - 10 V to
Base voltage + 80 V]
4-21
0 - 32
Default: 16
patterns
SP
0 - 32
Default: 16
0 - 32
Default = 16
‡ (only 2-101-
001 is on the
data sheet)
1 - 9
Default = 5 (0V)
1: Darkest
9: Lightest
1: –40 V
2: ±0 V
3: –80 V
4: –120 V
1 - 10
SP
Default = 6 (0V)
FT5535/4527/4522
Settings
(0V) ‡
(0V) ‡

Hide quick links: