8.4 PRESSURE ROLLER AND CLEANING ROLLER
REPLACEMENT
[C]
1. Remove the fusing unit (see "Fusing Unit Removal").
2. Remove the pressure springs and remove the lower fusing unit (4 screws).
3. Remove the lower fusing entrance guide [A] (2 screws).
4. Remove the pressure roller assembly [B].
5. Remove the fusing knob [C]
6. Replace the pressure roller [D] (2 C-rings, 2 bearings).
7. Replace the cleaning roller [E] (2 bushings).
NOTE: 1) When reinstalling the fusing entrance guide, tighten the screws while
pushing the guide plate up to the upper position (for standard or thin
paper). For thick paper, let the entrance guide plate drop to the lowest
position.
2) The standard pressure spring position is at the upper position.