E352: TD sensor initial setting error
- Definition - [D]
TD sensor output does not reach a value between 2.4 and 2.6 V when
performing the developer initial setting procedure.
- Possible Causes -
TD sensor defective
Main control board defective
TD sensor connector is disconnected.
E353: V
abnormal
SP
- Definition - [D]
The detected V
goes above 2.5 volts.
SP
- Possible Causes -
Dirty ID sensor
ID sensor board defective
Main control board defective
E354: V
abnormal
SG
- Definition - [D]
Detected V
is equal to or is below 2.5 volts.
SG
- Possible Causes -
Dirty ID sensor
ID sensor board defective
Main control board defective
E355: TD sensor upper limit detection abnormal
- Definition - [D]
TD sensor output exceeds 4.0 volts during copy cycles.
- Possible Causes -
TD sensor defective
Main control board defective
Toner supply system defective