REPLACEMENT AND ADJUSTMENT
15.7 PRESSURE ROLLER REPLACEMENT
[B]
CAUTION
The fusing unit may be hot.
1. Remove the fusing unit. (See Fusing Unit Removal.)
2. Remove the hot roller. (See Hot Roller Replacement.)
3. Remove the lower fusing entrance guide [A] (2 screws).
4. Remove the fusing knob [B] (1 screw).
5. Remove the pressure roller [C].
6. Replace the pressure roller (2 C-rings and 2 bearings).
NOTE: 1) When reinstalling the fusing entrance guide [A], use the center
screw holes [D] if the standard paper thickness setting is
acceptable. Otherwise, use the outer screws [E]; tighten the
screws while pushing the guide plate into the upper position (for
standard or thin paper). For thick paper, let the entrance guide
plate drop to the lowest position.
2) The standard pressure spring position is the upper one.
A207/A208/A211
[C]
[E]
[D]
1-108
[E]
[D]
[A]
A204R506.wmf
SM