1. Clean the covers.
11. Exterior (every 100
or 120 k)
Perform the following SP Modes in the following
order.
12. Copy Process SP
Mode Settings
1. SP2-214 TD Sensor Initial Setting
2. SP3-001 ID Sensor Initial Setting
3. SP3-112 Forced V
Detection
R
4. * SP4-001 Exposure Lamp Voltage Adj.
5. SP4-201 Auto ADS Gain Adj.
6. * SP3-105 Forced V
Detection
L
*: Perform these SP modes only if the exposure
lamp has been replaced.
Make a copy of an OS-A3 test chart at manual
13. Make a Copy
image density level 4.
FSM
4-63
FT5535/4527/4522