14. SERVICE TABLES (MAIN CONTROL
BOARD)
14.1 DIP SWITCHES
Dip Switch 100
Function
Standard setting
Raises all bins to the top position
Free run
Dip Switch 101
Dip Switch 102
Adjustment Value
Standard Position
0.5 mm
1.0 mm
1.5 mm
2.0 mm
2.5 mm
3.0 mm
3.5 mm
+ direction (See the illustration below.)
– direction (See the illustration below.)
NOTE: The adjustment value and the combination of the dip switch positions
are exactly the same for Dip Switch 101 and Dip Switch 102.
Dip Switch 101
SM
SERVICE TABLES (MAIN CONTROL BOARD)
1
0
1
0
Vertical Staple Position Adjustment
Horizontal Staple Position Adjustment
1
0
1
0
1
0
1
0
1
—
—
Feed
direction
↑ - direction
↓ + direction
3-27
0: OFF 1: ON
2
3
4
0
—
—
0
0
0
1
0
0
2
3
4
0
0
—
0
0
0/1
1
0
0/1
1
0
0/1
0
1
0/1
0
1
0/1
1
1
0/1
1
1
0/1
—
—
0
—
—
1
Dip Switch 102
+ direction
- direction
A664M500.wmf
A207/A208/A211
Feed
direction