Rev. 7/95
Power Consumption:
A153, and A156 copiers
Copier Only
Maximum
1.45 KW
Copying
1.00 KW
Warm-up
0.90 KW
Stand-by
0.16 KW
1
0.15 KW
2
0.13 KW
Energy
3
0.12 KW
Saver
4
0.11 KW
5
0.09 KW
6
0.07 KW
Auto Off
0.02 KW
NOTE: 1) Full System: Copier + ADF + Paper Tray Unit + 20 Bin S/S
2) Energy Saver: See SP1-105-002
3) Auto Off: See SP5-305
Maximum
Copying
Warm-up
Stand-by
1
2
Energy Saver
3
4
5
Auto Off
NOTE: 1) Full System: Copier + ADF + Paper Tray Unit + 10 Bin S/S
2) Energy Saver: See SP1-105-002
3) Auto Off: See SP5-305
Noise Emission:
Copier Only
1. Sound Power Level
Copying
Warm-up
Stand-by
2. Sound Pressure Level at the operator position
Copying
Warm-up
Stand-by
NOTE: The above measurements are to be made according to ISO 7779.
* : Full System: Copier + ADF + Paper Tray Unit +10 Bin S/S.
FT5535/4527/4522
Full System
1.50 KW
1.00 KW
0.92 KW
0.19 KW
0.17 KW
0.15 KW
0.14 KW
0.12 KW
0.11 KW
0.09 KW
0.04 KW
A161 and A162 Copiers
Copier Only
1.45 KW
0.64 KW
0.95 KW
0.15 KW
0.14 KW
0.12 KW
0.09 KW
0.07 KW
0.05 KW
0.02 KW
A153, and A156 copiers
Full System*
66 dB(A)
68 dB(A)
41 dB(A)
41 dB(A)
41 dB(A)
41 dB(A)
58 dB(A)
57 dB(A)
33 dB(A)
27 dB(A)
33 dB(A)
27 dB(A)
1-2
A157, and A160 copiers
Copier Only
Full System
1.45 KW
1.50 KW
0.80 KW
0.80 KW
0.90 KW
0.92 KW
0.15 KW
0.17 KW
0.14 KW
0.16 KW
0.12 KW
0.13 KW
0.09 KW
0.10 KW
0.07 KW
0.08 KW
0.05 KW
0.06 KW
–
0.02 KW
0.04 KW
Full System
1.50 KW
0.72 KW
0.97 KW
0.17 KW
0.16 KW
0.13 KW
0.10 KW
0.08 KW
0.06 KW
0.04 KW
A157, and A160 copiers
Copier Only
Full System*
61 dB(A)
67 dB(A) (L
39 dB(A)
40 dB(A) (L
39 dB(A)
40 dB(A) (L
54 dB(A)
56 dB(A) (L
32 dB(A)
27 dB(A) (L
32 dB(A)
27 dB(A) (L
–
)
WA
)
WA
)
WA
)
PA
)
PA
)
PA
FSM