Ricoh FT5535 Service Manual page 569

Hide thumbs Also See for FT5535:
Table of Contents

Advertisement

SERVICE PROGRAM MODE
Mode No.
Fusing
Temperature
Adjustment
1-105-001
(Main Fusing
Lamp) †
Fusing
Temperature
Adjustment for
Energy Saver
Mode †
1-105-002
Fusing
1-105-003
Temperature
(Type 2
Adjustment
only)
(Secondary
Fusing Lamp) †
Fusing
Temperature
Display (Main
1-106-001
Fusing Lamp) †
Fusing
Temperature
1-106-002
Display
(Type 2
(Secondary
only)
Fusing Lamp) †
Forced Start †
1-108
A207/A208/A211
Function
Adjusts the temperature of the main
fusing lamp, which heats the central area
of the hot roller.
The selected temperature is displayed in
the reduce/enlarge indicator.
(1°C per step [Range: 170°C to 190°C])
Adjusts the temperature of the fusing unit
in energy saver mode.
(SP5-102 and SP5-305 are also related
to Energy Saver Mode.)
SP Setting
Type 1
0
185°C
1
170°C
The lower the fusing temperature is, the
greater the energy saving ratio is and the
longer the waiting time until the copier
returns to the ready condition.
Adjusts the temperature of the
secondary fusing lamp, which heats both
ends of the hot roller.
(1°C per step [Range: 170°C to 190°C])
Displays the temperature (°C) at the
surface of the central area of the hot
roller, as measured by the thermistor.
The temperature in energy saving mode
cannot be displayed, as entering SP
mode takes the machine out of this
mode.
Displays the temperature (°C) at the
surface of the ends of the hot roller, as
measured by the thermistor.
The temperature in energy saving mode
cannot be displayed, as entering SP
mode takes the machine out of this
mode.
Selects whether forced start is on or off.
If forced start is switched on, the copier
enters the ready condition even if the
fusing temperature has not reached the
required value yet. Use this for tests if
the room temperature is low and you do
not wish to wait for the lamps to warm up.
1-66
Settings
170 ~ 190
Default = 185
(Type 1)
Default = 180
(Type 2)
Default = 1
(NA)
Default = 0
(Others)
Type 2
175°C
145°C
170 ~ 190
Default = 175
0: OFF
1: ON
SM

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ft5035Ft4022Ft4527Ft4027Ft4522

Table of Contents