Tech Service Bulletin No. 4027/4527/5035/5535/4022/4522 - 028
Page 3 of 4
2. Turn the Drum Unit over and attach the Mylar (A1533591) in the position shown.
Front
Make sure that the 2-sided adhesive tape does not stick out beyond the end of the upper guide and
that the mylar is flat.
3. Install the new style Entrance Guide Plate (A1533901). See illustration on page 4.
ADDITIONAL INFORMATION:
The Entrance Seal Ass'y shown in the illustration has been assigned a Part Number to make the
replacement of the seals easier.
* Please refer to page 2 of 4 for the positions of the seals #2, #20
A1533075
IMPORTANT: Use caution when
re-installing this item so as not to
snap the tabs off either end.
Upper Guide
20
A : 0 ~ 0.5 mm
B : 0 ~ 2 mm
IMPORTANT: DO NOT remove these screws
C3
Rear
Continued...