Rev. 7/95
5.
SERVICE TABLES (MAIN BOARD)
5.1
DIP SWITCHES
DIP SW 100 - Combinations other than those below are used only at the factory.
1
2
3
4
0
0
0
0
1
0
0
1
0
1
0
1
1
0
0
0
0
0
To make a free run
1. Select the required free run mode with switches 2 and 3.
2. Set switch 1 to 1. The free run starts.
3. To end the free run, set switch 1 to 0, then set switches 2 and 3 back to 0.
Remarks
#1
The roller drive motor turns on (alternately at low and high speed).
The sorting operation is repeated from the 1st bin to the 20th bin.
Operated components:
#2
Stapling is repeated from the 1st bin to the 20th bin. (If there are
staples in the staple unit, the stapling operation is skipped. If there is
paper in the bins, the jogger motor does not turn on.)
Operated components:
#3
#1 and #2 are repeated together alternately.
5.2
LED AND VARIABLE RESISTOR
LED No.
VR No.
100
5.3
TEST POINTS
Number
TP100
TP101
TP102
FT5535/4527/4522
5
0
Normal Machine Operation
0
Sorter Free Run
0
Stapler Free Run
0
Sorter & Stapler Free Run
1
Bin Sensor Adjustment (see section 6.6.2)
•
Turn gate solenoid
•
Bin lift motor
•
Jogger motor (for A4 sideways)
•
Bin lift motor
•
Grip motor
•
Stapler motor
•
Jogger motor (for A4 sideways)
100
Adjusts bin sensor sensitivity
Function
GND
+24V
+5V
10-14
Function
Function
Remarks
#1
#2
#3
FSM