the RMDS
and the IMDU operate
with full-duplex
communication
for remote
maintenance
(seven bits,
even parity, one-stop
bit). If the IMDU is employed,
a
dedicated
CO line or standard
telephone
port is not
required.
Connection
of the remote
maintenance
terminal
is through
existing
system
CO lines
by
transferring
the call by dialing
# 19
or via Direct
Inward Dial (DID) CO lines (see Program
*09 or 71-l
(l-3)
to program
RMDS
or IMDU,
DID extension
number).
Refer to the RSIU, RSSU, PIOU or PIOUS
portion
of Chapter
4-Printed
Circuit
Boards
for
hardware
installation and programming
requirements.
External
Maintenance
Modem
Installation:
Refer to
Figures
13-2 or 13-3, as applicable,
and install the
external
modem
in accordance
with the following
steps:
Note:
The Toshiba PPTC RS-232 modular-to-D925
adapter
is factory
configured
for ASCII
terminal connection.
Pins 2 and 3, and Pins 8
and 20 of the adapter
must be reversed
for
external modem connection
(see Table 13-l).
1.
Connect
the modular
cord from the RSIU, RSIS,
RSSU, PIOU, or PIOUS TTY port to the PPTC
adapter
and then to the external
maintenance
modem RS-232 25-pin connector.
2.
Connect
the external
maintenance
modem
line-
side to a dedicated
CO line (tip and ring) or to a
dedicated
standard
telephone
port, tip and ring.
Refer
to Chapter
7-Wiring
Diagrams
for
wiring/interconnecting
details.
3.
Set the PIOU or PIOUS SW2 switch to match the
modem or terminal baud rate:
Push in for 300 bps (baud rate indicator CD4 is lit);
let out (by pushing again) for 1200 bps (CD4 is not
lit).
4.
Set the PIOU or PIOUS SW3 switch to the TTY
position.
Note:
The PIOU or PIOUS SW3 switch is set to the
MODEM position for IMDU operation
only.
5.
Set the P13 jumper plug on the PIOU to the BELL
configuration,
or cut the W4 jumper on the PIOUS
(also for BELL configuration).
6.
7.
Note:
The P13 (PIOU)
and
W4 (PIOUS)
CCITT
configurations
are not normally
used in the
USA.
The communication
parameters
for the terminal
that will be used to communicate
through
the
external modem connected
to the TTY port should
be set to seven-bits,
even parity, one-stop bit.
Programming
and system testing, via the external
maintenance
modem,
is described
later in this
section.
To access to the external
maintenance
modem:
n
If the modem is connected
to a dedicated
CO
line, call the CO line number
to establish
modem communication.
4
If the modem
is connected
to a standard
telephone
port, call a Strata DK280 CO line
that can be transferred
to (or programmed
to
ring) the standard
telephone
modem
port to
establish
modem
communication.
It is also
possible
to establish
communications
by
calling in on a Strata DK280 DNIS, DISA, DID,
or Auto Attendant,
CO line and dialing
the
Directory Number of the modem connected
to
the standard telephone
port.
RMDSAMDU
Maintenance
Modem
Installation:
If
RMDS or IMDU is used, install the RMDS unit per the
instructions
provided
in the
RSIU
section
of
Chapter 4-Printed
Circuit Boards.
13.4.4
Programming
If an IMDU
or RMDS
and/or
280Admin/Backup
is
used,
enable
the
IMDU
or
RMDS
and/or
280AdmitVBackup
in Program
77-l
and Program
76
for RMDS.
If Remote Administration
and Maintenance
calls are to
connect
to the IMDU or RMDS automatically,
assign
the designated
ground/loop
start CO lines to ring the
IMDU or RMDS intercom or directory number
(#19) in
Program
78 as required
or assign
DID/tie/DNIS
CO
lines in Program
*09
or 71-1 (1 - 3) (use standard
Strata DK280 programming
procedures).
Program
the security codes for Levels 1 and 2 as in
the Chapter
g-programming
Instructions.
Reference
Program 00.
13-4
January