Toshiba Strata DK 280 Installation Manual page 156

Digital business telephone system
Hide thumbs Also See for Strata DK 280:
Table of Contents

Advertisement

4.12
E & M Tie line Unit
(PEMU/REMU)
Each PEMU and REMU PCB provides
four tie line
interface
circuits. With DK280R3,
tie lines can route
per Program 04 [DN] assignments
or Program 71 and
72 DNISANI
assignments
(see Program
17). The
differences
between
the REMU and PEMU are noted
as follows:
n
REMU tie lines may be individually configured
with
Type 1 or Type 2 signaling.
PEMU tie lines are
fixed at Type I signaling.
n
The REMU has four decibel (dB) PAD* switches
which can be set to reduce excessive
loudness
resulting from close proximity to a Central Office
or PBX by providing a -3dB signal level drop to the
PBX or Central
Office.
The PEMU does
not
provide these PAD switches.
*PAD
is for Transmit
and
Receive
for 2W
operation, and Transmit only is for 4W operation.
n
The REMU
can be programmed
for Wink or
Immediate
Start signaling. The PEMUl is fixed for
Immediate Start signaling.
Both REMU and PEMU may be configured
for either
2- or 4-wire transmission.
Note:
For the system to recognize the DTMF tones
generated
by incoming
tie lines, an RRCS
(-4, -8, or - 12) must be installed
on the
RCTUA,
RCTUB,
RCTUBA
or RCTUC/D.
RRCS is not required
for REMLYPEMU
dial
pulse operation (see Program 30, LED 1 I).
PEMUl
controls, indicators, and interface connectors
are shown
in Figure
4-28 and described
in Table
4-20.
REMU
controls,
indicators,
and interface
connectors
are shown in Figure 4-27 and described in
Table 4-21.
4.12.1
PEMU/REMU
Hardware
Options
There
are no hardware
options
supported
by the
PEMU or
m3~w.
4.12.2
PEMU/REMU
Installation
Procedures
Install the PEMU or REMU in accordance
with the
following steps:
1.
2.
3.
4.
5.
6.
7.
Remove the PCB from its protective packaging.
Determine
if the E & M tie lines will be configured
for 2- or 4-wire transmission
on PEMU. Set the
2W/4W
jumper
plugs
P103,
P203,
P303, and
P403 to the appropriate
positions on REMU set
SW103 m sw403.
For the PEMUl
only: Set the FG jumper plug P3
to the "2-3" position.
The REMU does not have
this jumper plug.
For the PEMU only: Set all GND/BAT
jumper
plugs to the "BAT" position for connection
to the
telephone
network.
The REMU does not have
these jumper plugs.
Note:
The "GND"position
is used to connect PERU
circuits back-to-back
on ,premises only, 1000
feet maximum
(E & M lead wires must be
crossed).
For the REMU only: set the P102/104,
P202/204,
P302/304,
and P402/404 jumper plugs for Type 1
or Type 2 signaling. The PEMU is fixed at Type 1
signaling and does not have these jumper plugs.
For the REMU
only:
If the DK280
cabinets
(DKSUB280
and DKSUE280
or DKSUE424)
are
within one mile of the PBX or Central Office, set
the REMU db PAD switches
SW1 01, SW201,
SW301, and SW401 to the "3" (-3db signal level
drop) position. The PEMUl
does not have these
switches.
Insert the REMU or PEMU into the appropriate
slot (refer to Subsection
4.1.2),
and apply firm,
even
pressure
to ensure
proper
mating
of
connectors.
IMPORTANT
!
Each
PEMU
or REMU
decreases
the
maximum
system CO line and Station Ports
by
four
each.
See
Worksheet
2
of
Chapter
l-Configuration
for recommended
REMU/PEMU
slot assignments.
8.
After installing the REMU or PEMU, gently pull it
outward.
If the connectors
are properly mated, a
slight resistance will be felt.
4-40
February
1996

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents