10. Check each door lock button from each station:
The HDCB
modular
B-jack
(pins 3 and 4) will
momentarily
close (three or six seconds) when the
appropriate
door lock button is pressed.
Note:
The HDCB W2 strap is not used with Strata
DK280 systems.
The strap provides
an alarm
function with other Strata systems.
6.3.2
DDCB
and
HDCB/DRLK
Assignments
Guide
Table
6-1
DDCB and HDCB/DRLK
Assignments Guide
DDCB/
RDSWPDKW
Port
HDCB
Program
39 Button
PEKWPESU
No.
No.
Assignments
First (fifth circuit,
004
1
Unlock Door 1
slot 11)
(DRLK I), Code 72
Second
(fifth circuit,
012
2
Unlock Door 2
slot 12)
(DRLK 2), Code 73
Third (fifth circuit,
020
3
Unlock Door 3
slot 13)
(DRLK 3), Code 74
Fourth (fifth circuit,
028
4
Unlock Door 4
slot 14)
(DRLK 4), Code 7.5
DK031
Notes:
1.
See Programs
39, 77-1,
and
77-2 to
program
assignments.
2.
DDCB
and
HDCB
hardware
option
settings for door lock control operation:
n
Set SW1 ('jumper) to DOOR position.
n
Set SW2 (switch) to LOCK position.
6.3.3
NHT/NHR
Options
with
PIOU,
PIOUS,
or PEPU
The NHT/NHR
may be programmed
for either the
Night
Relay or the MOH relay function.
(Refer
to
Figures 6-7 and 6-8.)
Note:
Only the PIOU/PIOUS,
or PEPU with the
lowest Program
03 code (4 1, 42 or 43) will
provide the NT or MOH relay control function.
When
configured
for
the
NT
function
with
Program
77-1, the relay activates
if the system is in
the NIGHT mode. The relay may be programmed
to
activate continuously
when the Night Transfer
button
(only)
is set for the
NIGHT
mode
(for
indirect
answering
machine
control),
or to pulsate
at one-
second ON/three-seconds
OFF (for a night bell) when
incoming
CO lines ring (NT1 = tenant
1 CO lines -
NT4 = tenant 4 CO lines) per Program *15 and 77-3.
When configured
for the MOH function
with Program
77-1, the relay activates any time a CO line is on hold.
In this configuration,
the relay is normally
used to
control the MOH source.
NHT Control
Configure
the PIOU, PIOUS,
or PEPU for the NHT
function
in accordance
with the following
steps (refer
to Figures 6-7 and 6-8):
1.
2.
3.
4.
5.
6.
7.
Access
Program
77-l.
Set LED 05 to OFF to
configure
the Night/Hold
Relay
for the NHT
function.
Access
Program
77-l.
Set LED 06 to provide
continuous
or pulsating relay activation as follows:
4
OFF-Programs
the relay for continuous
activation
when the Night
Transfer
(NT)
button (only) is set in the NIGHT mode.
n
ON-Programs
the
relay
for
pulsating
activation
when the Night
Transfer
(NT)
button for tenant
1 - 4 is set to the NIGHT
mode and a CO line rings.
Note:
CO lines must be enabled
in Program
78 for
the NT pulsating relay function.
Access Programs
87, 88, and 89 to set the CO
lines that will activate the relay (when the system
is in the NIGHT mode).
Access Program 39 to assign Night Transfer
(NT)
buttons
to telephones
that should be able to set
the Strata DK280 system into the NIGHT mode.
Access Programs 29-l
- 29-4 to program
a Night
Transfer
button
on all direct
station
selection
consoles
that are to transfer
the Strata
DK280
system into the NIGHT mode.
If tenant
operation
is required,
access
Program
*I5 to set the CO lines for tenant
1 - tenant
4
operation.
RCTUA
and RCTUB
provides
two
tenant assignments,
RCTUCYD provides four.
If using a PIOU or PEPU, set the Pi 1 jumper plug
on the PIOU or PEPU to the MAKE or BREAK
. . .
position, as required:
..:
,
6-14
January
1996