Station Apparatus; Types Of Telephones; Telephone Installation - Toshiba Strata DK 280 Installation Manual

Digital business telephone system
Hide thumbs Also See for Strata DK 280:
Table of Contents

Advertisement

Station Apparatus
This chapter provides
instructions
on how to connect
telephones
to the Strata DK280 system
and how to
configure
and upgrade
them for optional
features.
Procedures
for installing
direct
station
selection
consoles,
PC and conventional
attendant
consoles,
and door phones also appear in this chapter.
5.1
Types of Telephones
The Strata DK280 systems can support the following
telephones.
W Digital
Telephones:
Installation
instructions
for
digital telephones
in this chapter and elsewhere
in
this manual apply only to the Toshiba
2000- and
1 OOO-series digital telephones.
The 2000-series
digital
telephones
consist
of four models:
the
DKT201
O-H, DKT201 O-SD,
DKT2020-S,
and
DKT2020-SD.
There
are two lOOO-series digital
telephone
models, the DKT1020-H
and DKT1020-
SD.
1
Electronic
Telephones:
The electronic telephone
instructions
here apply to the Toshiba 6500-series
electronic
telephones,
although
there are other
electronic
telephones
(the 2000-,
3000-,
6000-,
and 6500-series)
that are compatible
with the
Strata
DK280.
The
6500-series
electronic
telephones
consist
of
four
models:
the
EKT6510-H,
EKT651
O-S, EKT6520-H,
and
EKT6520-SD.
n
Standard
Telephones:
500-
and 2500-type
standard
telephones
apply whenever
standard
telephones
are mentioned
in this manual.
5.2
Telephone Installation
This section describes the wiring required to connect
telephones
to the system.
Before
installing
any
telephone
wiring,
read the following
warning
and
caution notes:
1.
2.
3.
4.
5.
WARNING !
Never
install
the telephone
wiring
during a lightning
storm.
Never install the telephone
jacks in wet
locations,
unless
the
jack
is
specifically
designed
for
wet
locations.
Never
touch
uninsulated
telephone
wires
or
terminals
unless
the
telephone
line has been disconnected
at the network
interface.
Use
caution
when
installing
or
modifying
telephone
lines.
If telephone,
DSS console,
door phone
control
box, or door phone
wiring exits
the
building,
external
secondary
protection
is required.
See Chapter
7-
Wiring Diagrams.
CAUTION !
When installing
the station cable, do not run
the cables parallel if they are within three feet
of an AC power
line. AC power
lines should
be crossed
at right
(90")
angles
only.
In
particular,
avoid
running
station
wire pairs
near devices
that generate
electrical
noise,
such as neon or fluorescent
light fixtures.
January
1996
5-1