Toshiba Strata DK 280 Installation Manual page 258

Digital business telephone system
Hide thumbs Also See for Strata DK 280:
Table of Contents

Advertisement

+
The screen
on PC 1 displays,
CONNECT
xxxx,
where
xxxx
is the data transmission
speed set by the communications
software.
+
At this time,
PC 1 and PDIU-DS
204 are
connected
as shown by the thick lines above
(PDIU-DS 204 is in the communication
mode).
PC 1 is now linked directly to the RS-232 side
of the internal
modem
and can issue
AT
commands
to the internal
modem,
which
is
now in the command
mode.
+
If Digital/PDIU-DS
port 004 is the only DIU
port connected
to the modem
(Program
20,
LED 03 ON), the Modem
LEDs on all DKTs
will be lit.
W
From PC l's keyboard, type ~~~~#70016744700
and press Enter.
+
The internal modem (208) goes off-hook, dials
#7001 to seize the CO line, and then dials the
external
modem's
telephone
number
(674-
4700).
+
The external modem rings and auto answers;
the
modems
handshake
and
establish
communications.
4
If the modems
send result codes, the screen
on PC 1 displays,
CONNECT
xxxx,
where
xxxx
is the data transmission
speed set by
the communication
software.
n
At this time PC 1 and PC 2 are connected,
as
shown by the thick lines above, to exchange
data (file transfers, type messages,
etc.).
W To terminate
the call: press the telephone
Data
Release button and;
A.
B.
Type +++ from PC2 keyboard.
+
The PC screen displays, OK.
Type
ATH from
the PC keyboard
used
in
Step A.
+
PC 1 and PC 2 screens both display, NO
CARRIER.
+
The data call LED on DKT 200 will turn
Off.
External
PC to Internal
PC Test Call Using AT
Commands
Over a Direct
CO Line
(see Figure 6-38)
4
RPCI or DIU Programming:
+
Program
20: Port 000. LEDs 01, 02, 05, and
17 ON; all other LEDs OFF.
+
Program
20: Port 004. LEDs 01, 02, 04, and
17 ON; all other LEDs OFF.
+
Program
39: Port 000. Data Call (456) and
Data
Release
(454)
buttons
should
be
provided.
+
Internal
modem:
set the
following
AT
commands:
Auto answer
(ATS0=1),
disable
character
echo in the command
state (ATEIZI),
modem
returns
result
codes
(ATQIZI),
presence
of data carrier (AT&Cl),
hang up
and assume
command
state with DTR on-to-
off transition
(AT&D2).
+
Settings for PDIU-DS: rear panel switches 1,2
and 4 ON; internal jumpers
Pi-P9 set to B-C
position.
H
Make sure PC 1 and PC 2 are on-line
with a
communications
software
package
and that the
communication
parameters
of each
PC and
communication
software
package
are set to the
same values (data transmission
rate, parity, data
bits, stop bits, flow control, etc.)
Note:
If using an RPCI-DI,
it may be necessary
to
switch
the RPCI from the API mode
to the
Data
Communications
Mode
before
proceeding
with Step 3. To place the RPCI
into the data communications
mode from the
PC keyboard:
Set NIUII Lock to ON and type
240
while holding
the Alt
key down (this is
HEX FO). If in the data communication
mode
ATCO will switch the RPCI-DI back to the API
,
mode.
H
From PC 2's keyboard,
type ~~~~5833700
and
press Enter.
The external
modem
originates
the call to
internal modem.
The internal modem
rings and auto answers;
the
modems
handshake
and
establish
communications.
The ready light on the PDIU-
DS turns on.
If the modems
send result codes,
the PC's
screens
display,
CONNECT
xxxx,
where
xxxx
is the data transmission
speed set by
the communications
software.
At this time, PC 2 is connected
to PDIU-DS
(204),
as shown
by the thick
lines above
(PDIU-DS 204 is in the command
mode). PC
2 can now issue AT commands
to PDIU-DS
204.
6-58
January1996

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents