DK280 Tl General Installation
Information
,
11.2.1
RDTU
Channelization
The Strata
DK280
RDTU
PCB provides
Ti/DS-1
interface
up to 24 channels.
Each channel
can be
individually
set for loop start, ground start, tie, or DID
line operation
(voice only, not data lines). Each RDTU
can be set in system programming
to activate
(l-8),
(l-16),
or (l-24)
channels
(lines).
Fractional
increments
of 4, 12, and 20 are also possible but the
RDTU
will
still
assign
8, 16,
or 24
channels
respectively
in system software.
Example:
If only 12
channels of fractional Tl are used, assign RDTU as a
16 channel RDTU. The system will assign 16 CO lines
to the RDTU even though
only 12 CO lines will be
used.
To busy out unused
RDTU
channels
(see
Section
11.4,
Step 4). Use Program
03 to set the
quantity of RDTU channels.
11.2.2
RDTU
Slot Assignments
Up to six RDTU PCBs can be installed in a DK280 to
provide up to 144 lines. RDTU PCBs can be installed
in the same cabinets
that have analog
type CO line
PCBs installed.
RDTU
PCBs
must
be placed
in
designated
slots in each of the DK280 cabinets.
If an
RDTU is installed in a cabinet (in some cases one or
two slots to the right of the RDTU may not be used in
that cabinet) the number of unusable
slots in a cabinet
(none,
1 or 2) depends
on which
slot the RDTU
occupies and how many lines (8, 16, or 24) the RDTU
is programmed
to provide (see Tables 1 l-1, 1 l-2 and
1 l-3 for RDTU slot installation
rules). Use Program 03
to set the RDTU
slot assignments
and Channel
quantities
(Code 71 = 8 ch., Code 72 = 16 ch., and
Code 73 = 24 ch.).
11.3
DK280 RDTU (Tl) Applications
Each RDTU Tl PCB requires the following connecting
equipment
and cables to provide service:
11.3.1
RDTU
to Network
If the RDTU
must interface
to a public
telephone
network or common
carrier Tl circuit, the RDTU must
be connected
to a Channel
Service Unit (CSU). Use
the NDTU cable (30 ft. cable supplied with RDTU) to
connect the RDTU to the CSU (see Figure
1 i-l).
The
function of the CSU is to provide the required interface
between
the
DK280
RDTU
PCB and the Public
Telephone
or Carrier Network.
The interface
created
by the
CSU
normally
provides
protection
and
capabilities
for loop back testing
both the Network
equipment
and the DK280 RDTU PCB.
_
Connecting
the CSU to the Network
Interface
Unit
(NIU) is specified by the CSU manufacturer-see
CSU
installation
documentation.
Toshiba
does not supply
the cables and connectors
required
to connect
the
CSU to the
NIU (see Subsection
11.5.4
of this
chapter).
11.3.2
RDTU
to PBX Tl (Separated
More
Than
655 ft.)
If the RDTU must interface
to a customer's
premises
Tl circuit (PBX, key/hybrid,
or another
DK280)
to
provide tie line service, the RDTU must be connected
to a CSU (with Toshiba
NDTU
cable)
if the other
customer
premise
Tl equipment
is more than 655 ft.
STRATA
DK280
TOSHIBA
PBX OR
,
,
NDTU
cable
CABLE
CABLE
KEY/HYBRID
RDTU
I
More than 655 ft.
General Note:
l
Cable A, B and connectors are special cables
supplied by customer (see Subsection
11.5.4).
DK0510
Figure
11-2
RDTU
Connection
via CSU
from the RDTU. The Tl span on the other end must
also connect to a CSU (see Figure 11-2).
The RDTU equalization
switch (SWl) must be set for
"SHORT"
cable
length
because
RDTU
will be
connected
to the CSU with the 30 ft. NDTU cable (see
Table 1 l-4).
Connecting
CSU to CSU and CSU to the far-end PBX
Tl is specified
by the CSU manufacturer-see
the
CSU installation
documentation.
Toshiba
does not
supply cables or connectors
to connect
CSU to CSU
(Cable A) or CSU to the far end PBX (Cable B).