Remote Maintenance Modem (Imdu) Installation - Toshiba Strata DK 280 Installation Manual

Digital business telephone system
Hide thumbs Also See for Strata DK 280:
Table of Contents

Advertisement

Program
*41 Series-Assigns
RDTU channel
line
operation,
as well coding and framing modes.
Program
42-0,
1-8-Assigns
behind
PBXKentrex
operation
to each line.
Program
*42 Series-Assigns
timing
reference
for
RDTUs.
Programs
45 - 48-Define
Toll Restriction
for any
line.
Program
*50, *51, *52-Caller
ID/AN1 assignments.
Programs
50 - 56-Defines
Least
Cost
Routing
assignments.
Program
71 (1 - 5)-Tie/DID
DNIS assignment
(optional see Program 04/*09).
Program
*71 - *73-Tie/DID
telephone/[DN]
ring
assignments.
Program
78-Assigns
special
ringing
of lines:
includes
Night
Ring
Over
Page,
DISA,
Remote
Maintenance
via the Internal
Maintenance
Modem
(IMDU), and built-in Auto Attendant.
Program
81 - 89-Ground/loop
start
lines DAY,
DAY2, and NIGHT ringing assignments.
Program
*81, *84, *87-Assigns
[DN] LEDs to flash
when CO line rings a telephone.
4.15 Option Interface Units (PIOU
and PIOUS)
The PIOU and PIOUS both provide a circuit interface
with the system
peripheral
options.
A maximum
of
three PIOU or PIOUS PCBs can be installed
in the
system.
The PIOU and PIOUS
support
the same
options,
except the PIOUS does not support a built-in
amplifier or Zone Paging. (See Chapter 6-Peripheral
Installation,
Section 6.12)
PIOU controls,
indicators,
and interface
connectors
are shown in Figure 4-32 and described
in Table 4-24.
PIOUS
information
is provided
in Figure
4-33 and
Table 4-25.
4.15.1
PIOU
and PIOUS
Hardware
Options
The PIOU and PIOUS support the following
hardware
options:
Internal
Option
n
Remote Maintenance
Modem Unit (IMDU)
Install
the IMDU
on the PIOU or PIOUS
PCB in
accordance
with the following steps:
1.
Remove
the PIOU or PIOUS from its protective
packaging.
Remove
the IMDU from its protective
packaging.
J3
J2
-
\
0
DK0289
Figure 4-31
Remote Maintenance
Modem (IMDU)
Installation
2.
Set the SW3 switch to the "MODEM"
position for
IMDU operation.
3.
Set the P13 jumper
plug on the PIOU to the
"BELL" position; or, cut the W4 jumper wire on the
PIOUS for "BELL" operation.
L
4.
Mate IMDU
connectors
Ji, J2, and J3 (Figure
4-31) with PIOU or PIOUS connectors
Pl, P2, and
P3.
Note:
PIOU or PIOUS connectors
Pl, P2, and P3
are positioned
to allow
installation
of the
IMDU only in the proper position.
5.
Refer to Programming
Part and turn LED 14 on in
Program 77-l to enable IMDU operation.
Note:
The IMDU default station intercom or directory
number is # 19.
6.
Apply firm, even pressure
to the IMDU to ensure
proper mating of connectors.
7.
Set the SW2 baud rate 'switch on the front-panel
to
300 or 1200, as appropriate,
after the PCB has
January