Amplifier Requirements; Station Message Detail Recording (Smdr) Printer/Call Accounting Device Options - Toshiba Strata DK 280 Installation Manual

Digital business telephone system
Hide thumbs Also See for Strata DK 280:
Table of Contents

Advertisement

Note:
Only the outside party I talk path is amplified
to/from
a system
telephone
when
it is
connected
into a two-CO line conference.
6.6.1
Amplifier
Requirements
H
Customer-supplied
(four maximum).
n
Must be FCC-registered,
Part 68, and provide
automatic
gain control.
n
Each amplifier requires two PEKU station ports.
H
Refer to the amplifier
manufacturer's
installation
documentation
for amplifier grounding
instructions.
,
Installation:
Connect a two-way
amplifier to the Strata
DK280 system in accordance
with the following
steps
(see Figures
6-19 and the Amplified
Two-CO
Line
Conference
wiring
diagram
in Chapter
7-Wiring
Diagrams).
1.
At the main distribution
frame (MDF), connect the
voice pair (VT, VR, port A) of Circuit 2 on the
designated
PEKU
PCB to one
input
of the
customer-supplied
two-way
amplifier.
In the
example
in Figure
6-19, this is CKTA (Central
Office Side A) of the VFR5050.
2.
At the MDF, connect
the voice pair (VT, VR, port
B) of circuit 3 on the designated
PEKU PCB to the
other
input of the amplifier.
In the Figure
6-19
example,
this is CKTB (subscriber
side B) of
VFR5050.
3.
Plug the amplifier's
power cord into the 117VAC
(standard)
wall outlet.
4.
Set the gain and
other
amplifier
parameters
options
per
the
amplifier
manufacturer's
installation documentation.
5.
Program the Strata DK280 system as follows:
n
Program
lo-3-Enables
the appropriate
PEKU PCB ports for amplifier
connection.
Only enable the ports that will be connected
with the amplifier(s).
n
Program
15~5-Enables
appropriate
CO lines
for Two-CO line tandem connection.
n
Program
IO-I-LEDs
19 and 20 must be ON.
n
Program
IO-2-LED
18 must be ON.
Note:
LED 19 in Program
lo- 1 should be ON if it is
certain
that
an amplifier
will always
be
available
for
two-CO
line
conference
connections
(four maximum,
simultaneously).
If this
LED
is ON
and
a two-CO-line
connection
is established
without an external
amplifier,
the Strata
DK280
station
may be
unbalanced
and receive a hum noise. LED 19
provides
additional
station amplification
when
external
amplifiers
are switched
into two-CO
line connections.
6.7
Station Message Detail Recording
(SMDR) Printer/Call
Accounting
Device Options
An SMDR
printer or call accounting
device
may be
connected
to the system to provide a hard-copy record
(Figure 6-20 and 6-21) of station activity. The Strata
DK280
system
can record
incoming,
outgoing,
and
transferred
calls, as well as Account Code entries. Call
record data is printed out at the completion
of each
eligible call.
SMDR format is ASCII-formatted,
8-bits,
no parity, l-stop
bit. PIOU/PIOUS
will be 300 or 1200
bps (see Chapter 4-Printed
Circuit Boards) and RSIU
or RSIS can be 1200-9600
bps (see Program 76).
Program
SMDR
with
Program
60-The
SMDR port
will be active
only on the PIOU or PIOUS with the
lowest Program 03 code (41, 42, or 43). or the RSIU
or
RSIS
Port
programmed
with
code
x2
in
Program 76-l.
Note:
If PlOWPIOUS
and RSIWRSIS
are assigned
L
as SMDR
simultaneously
in programming,
RSIU/RSIS
will
operate
as SMDR-not
PlOWPIOUS.
A display of the customer
data
base (Figure 6-22) can also be printed
using
the SMDR RS-232 port by running
Program
97.
SMDR will send out special names for the following
types of calls:
n
MSS: Prints on Direct
Inward
System
Access
(DISA) and External Call Forward calls to stations
(see Note 2).
n
MODM:
Prints on calls to the RMDS
or IMDU
remote maintenance
modem (Station #I 9).
n
DISA: Prints on DISA and External Call Forward
calls in which CO lines are accessed for trunk-to-
trunk outside calling.
.
I
6-28
January
1996