Toshiba Strata DK 280 Installation Manual page 449

Digital business telephone system
Hide thumbs Also See for Strata DK 280:
Table of Contents

Advertisement

Program 12 -
System
Assignments
-
Basic Timing
Program Code
SELECT=3-9 -T -I-
SELECT CODE = Enter required
Enter program code,
code for the time listed in the
3 - 9, from table below.
table below. See Note 1.
Function
Code
Time
Required Code
34
42
5
85
Pause Timing
q 1
1.5 sec.
(Speed Dial)
q
2
3.0 sec.
q 1
0.5 sec.
Flash Timing3
q
2
2.0 sec.
q
4
0.2 sec.3
q 0
no pause
Pause After Flash
(Voice Path Delay)
q
1
1.5 sec.
q
2
3 sec.
q 0
No disconnect timer
DNIS Ext. Network
External Call Forward
q
1
4 minute disconnect
and DISA Disconnect
Timer for Loop Start Lines
q
2
10 minute disconnect
q
3
20 minute disconnect
RRCS Inter-digital Release
q 1
1 sec.
9
Time (Standard Phone)
through
through
q 9 9 sec.
Notes:
1. When programming
Code 8 and 9, the LCD responds with LINE TIME =, instead of SELECT
CODE =.
2. The duration of time the RCOU/RCOS
or PCOlJ circuit opens Tip
&
Ring when the
Flash
or
MW/FL
button is pressed, or hookflash code
CnfiTrn
(CONFiTRANS)
# 4 5 is dialed.
3. This timing is not used in the United States.
4. This timing applies to voice calls originated
from telephones
and data calls orginated by system
Data Interface Units.
5. DISA, Call Forward External and/or DNIS Telephone Network routed calls made on loop start
lines will be automatically
disconnected
when the DISAICF-EXTIDNIS
ext. Network timer
expires. Callers will hear a warning tone and can Dial "0" to reset this timer repeated/y.
This is to
prevent loop start line lock up if no CPC disconnect signal is provided by the central office when
outside caller hangs up.
General Notes:
l
For more information,
see the instructions preceding
the record sheets.
'
.
Initialized data programs timing as follows: Code 3 = 1, Code 4 = 2, Code 5 = 0, Code 8 = I,
Code 9 = 4.
February
1996