DDCB or HDCB
PDKU
- OR-
RDSU
- OR-
PEKU
-OR-
PESU
RELAY
CONTROL
CONTACT'
(SEE CHAPTER
7-
WIRING
DIAGRAMS)
(PORT 004,012,020,
'
OR 028)
DOOR LOCK
CONTROL
CONTACT*
HDCB WIRING CHART
DDCB WIRING CHART
RJI_1_ 8
, MDFB
-4
,2
DOOR PHONE
2 RELAY CONTACT
A
5 TO CUSTOMER
SUPPLIED
B
RJll
3
See Chapter
7-Wiring
for PEKU, PESU, PDKU or RDSU pin-out information.
Notes:
1. Relay control contact
will close when the door phone
is in the ringing,
talk, or monitor
state.
2.
See Subsection
6.3.1, paragraph
5, and Subsection
6.3.2.
3.
Relay contact specifications
are -24VDC at 1.0 amp. max. Do not connect
relay contacts
to 120 AC
DK031
commercial
po wer.
Figure
6-10
Multiple
Door lock Control Options (DDCB/HDCB)
HDCB
Installation
6.
See figure 6-10 and HDCB Wiring Diagram in Chapter
7-Wiring
Diagrams and follow these steps:
1.
Cut jumper W9 of the particular
PEKU or PESU
that will connect to the HDCB.
2.
Connect
the Circuit 5 VT/VR and DT/DR pairs to
the HDCB HKSU modular jack.
3.
Connect
the door
lock wire pair to the HDCB
modular B-jack (pins 3 and 4).
4.
On the HDCB, set SW1 to the DOOR position.
5.
On the HDCB, set SW2 to the LOCK position.
7.
6.
9.
W3 inside the HDCB can be set to open or close
the door lock relay whenever
a door lock button is
pressed:
if W3 is in the "solid-line"
position,
the
relay will provide
a closure
when
the button
is
pressed;
if in the "dotted-line"
position,
the door
lock relay will open when the door lock button is
pressed.
In Program
77-1, set the door lock activation
for
three or six seconds,
and enable the PEKU and
PESU ports for HDCB connection.
In Program 77-2, enable the HDCB B-jack for door
lock operation.
In Program
39, assigndoor
lock buttons
to the
desired stations per the customer's
record sheet.