11.3.3
RDTU
to PBX
Tl
(Separated
Less
Than
655 ft.)
If the RDTU is within 655 ft. of the far-end
PBX Tl
circuit,
a CSU is not required
(see Figure
1 l-3).
However, connecting
a RDTU Tl span to another PBX
or Key/Hybrid
Tl,
in a tie line configuration
at a
distance less than 655 ft. (without a CSU) will require
a customer
provided special cable (see Figure 11-3).
The transmit and receive pair of this span cable must
be separated
by at least five cable pairs and the wires
must be 24 AWG, twisted
pair, otherwise
22 AWG,
ABAM type cable must be used.
4
Two CSUs (customer
provided)
are required
if the
RDTU is more than 655 ft. from the customer
premise
channel
bank (Figure 11-4); CSUs are not required if
the RDTU is less than 655 ft. from the channel
bank
(Figure 1 l-3).
11.4 RDTU (Tl) System Programming
Installing a RDTU (Tl) into a Strata DK280 requires a
number
of system
programs
to
be run.
It is
recommended
to run these
programs
in the order
listed below before
actually
installing the RDTU into
the system.
This will allow the RDTU to function
immediately,
including
self-check
loop back testing
and normal
operation,
when
it is inserted
into the
system. Use the instructions
provided
below and use
the appropriate
systems
record sheets to record and
enter the data for each of the programs
listed.
1.
Run Program
OS-Assign
the number
of RDTU
channels
used and the cabinet
slot number
into
which the RDTU will be installed (see Subsections
11.2.1 and 11.2.2).
If 1-8 channel
are required,
assign code 71, if 1-16
channels
are required,
assign code 72, or if 1-24 channels are required,
assign code 73 to the RDTU slot. Also, assign
RRCS code to RCTU if RDTU tie/DID
channels
are DTMF.
IMPORTANT!
Special
consideration
must be taken
when
installing
tie or DID
Tl
channels
(see
Worksheet 2 of Chapter 1.
2.
Run Program
*41-2-Assign
each channel
for
loop start, ground start tie (Immediate
or Wink), or
DID (Immediate
or Wink)'. See Program
x41-2
record sheet
(unused
channels
can remain
as
initialized-loop
start).
3.
Turn system power supply OFF (five seconds) and
ON to activate
Program
03 and *41-2
program
data.
Note:
These
are the only programs
relating
to
RDTU operation
that require system power to
be cycled OFF and ON.
4.
Run
Programs
16, 40,
39-If
an RDTU
is
connected
to a fractional
Tl circuit and all the
STRATA DK280
R(1)
4
"41:"
T (26) 4
RI
(2) 4
Tl (27) 4
CUSTOMER
PROVIDED
SPECIAL
CABLE/CONNECTORS
RDTU
-
TRANSMIT
RDTU
+
RECEIVE
PBX OR OTHER CP
e
(2) Rr
PBWKEY
)
(27) Rt SYSTEM
-OR-
t
(1)Tr
CHANNEL
BANK
)
(26)
Tt
.RDTU AMPHENOL
CONNECTOR
1
(MAXIMUM
655 FT.) .
PBX AMPHENOL
(PIN NO.)
CONNECTOR
General Note:
l
Special cable and connectors provided by customer.
(See Subsection
11.54.)
,
DK0511
Figure 11-3
Required Cables/Connectors
for RDTU Connection
at Distances of Less Than 655 Feet (200 Meters)
11-4
January
1996