IMPORTANT!
To protect against transient
voltages and currents,
solid state secondary
protectors
must be installed if
there is outside wiring (Figure 7-l), and on all DID and E&M tie lines. These protectors,
which contain
fast semiconductors
in addition to fuses, shall comply with the requirements
for secondary
protectors
for
communication
circuits, UL 497A. Care must be taken to ensure that they are very well grounded
to a
reliable earth ground. Recommended
protectors
are available in the fast Series 6 line from Oneac Corp,
Libertyville,
Illinois 60048,
800-327-8801.
Install and test the secondary
protect&s
precisely
to the
installation instructions
of the manufacturer.